Evaluation of impedance matching schemes for pulse-echo ultrasonic piezoelectric transducers

被引:0
|
作者
San Emeterio, JL
Ramos, A
Sanz, PT
Ruiz, A
机构
[1] CSIC, Inst Acust, Madrid, Spain
[2] ICIMAF, Dept Ultrason, Havana, Cuba
关键词
piezoelectric transducers; ultrasonics; matching layers; tuning;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to optimize the broadband response of a piezoelectric transducer, different impedance matching procedures are used, looking for a compromise between efficiency and bandwidth. In this paper a general methodology for the evaluation of acoustic and electrical matching schemes is presented. Broadband acoustic impedance matching schemes are evaluated in the frequency domain using the transmission line analogy. Electrical matching networks at the reception stage are evaluated using the transmission matrix approach. In practical cases of ultrasonic imaging and NDE, electronic "spike" generators based on capacitive discharges are used. The special topology of such generators (including semiconductor devices) conditions the electrical driving pulse at the transducer terminals. This driving waveform (determined by the interactions among the spike generator, the electrical matching network and the transducer) is approximately evaluated in the frequency domain for the low Megahertz range. Several examples in emission and reception illustrate the methodology, including a comparative study of criteria proposed for the,optimum design of quarter-wave transmission line matching layers.
引用
收藏
页码:2675 / 2680
页数:6
相关论文
共 50 条
  • [21] ECHO STRUCTURE IN MEDICAL ULTRASONIC PULSE-ECHO SCANNING
    GORE, JC
    LEEMAN, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 431 - 443
  • [22] MATLAB/Simulink Pulse-echo Ultrasound System Simulator with Electrical Impedance Matching
    Shin, Sangmin
    Kim, Taehoon
    Kim, Suhwan
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2018, 18 (03) : 328 - 336
  • [23] Errors and uncertainties in the ultrasonic pulse-echo reflectometry method for measuring acoustic impedance
    Challis, RE
    Wilkinson, GP
    Freemantle, RJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (04) : 692 - 700
  • [24] TONE-BURST TESTING OF PULSE-ECHO TRANSDUCERS
    ERIKSON, KR
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1979, 26 (01): : 7 - 14
  • [25] ULTRASONIC PULSE-ECHO TECHNIQUE FOR VHF RANGE
    HEMPHILL, RB
    PENN, TC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (12): : 1809 - &
  • [26] ULTRASONIC PULSE-ECHO INSTRUMENT LINEARITY MEASUREMENT
    BAILEY, JA
    MATERIALS EVALUATION, 1977, 35 (05) : 64 - 68
  • [27] PULSE-ECHO ULTRASONIC FINGERPRINT SENSOR ON A CHIP
    Tang, H.
    Lu, Y.
    Fung, S.
    Tsai, J. M.
    Daneman, M.
    Horsley, D. A.
    Boser, B. E.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 674 - 677
  • [28] Piezoelectric Micromachined Ultrasonic Transducer With Superior Acoustic Outputs for Pulse-Echo Imaging Application
    Fu, Yuedong
    Sun, Sheng
    Wang, Zhuochen
    Niu, Pengfei
    Zhang, Menglun
    Chen, Shili
    Pang, Wei
    IEEE ELECTRON DEVICE LETTERS, 2020, 41 (10) : 1572 - 1575
  • [29] PREDICTED ULTRASONIC RESPONSES FOR PULSE-ECHO INSPECTIONS
    TEMPLE, JAG
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1986, 28 (03): : 145 - 154
  • [30] Characterization of an ultrasonic transducer in a pulse-echo setup
    Lopez-Sanchez, A
    Schmerr, LW
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 25A AND 25B, 2006, 820 : 900 - 907