Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms

被引:10
|
作者
Al Hatib, F
Trendafilova, E
Daskalov, I
机构
[1] Bulgarian Acad Sci, Ctr Biomed Engn, BU-1113 Sofia, Bulgaria
[2] Natl Ctr Cardiovasc Dis & Rehabil, Sofia 1309, Bulgaria
关键词
defibrillation; transthoracic impedance; modelling;
D O I
10.1088/0967-3334/21/1/318
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low amplitude high frequency current) of the impedance were considered a solution for selection of adequate shock voltages or for current-based defibrillation dosage. A recent approach, called 'impedance-compensating defibrillation' was implemented, where the pulse duration was controlled with respect to the impedance measured during the initial phase of the shock. These considerations raised our interest in reassessment of the transthoracic impedance characteristics and the corresponding measurement methods. The purpose of this work is to study the variations of the transthoracic impedance by a continuous measurement technique during the defibrillation shock and comparing the data with results obtained by modelling. Voltage and current impulse waveforms were acquired during cardioversion of patients with atrial fibrillation or flutter. The same type of defibrillation pulse was taken from dogs after induction of fibrillation. The electrodes were located in the anterior position, for both the patients and animals.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 50 条
  • [31] Comparison between modelled and measured heat transfer rates during the departure of a steam bubble from a solid surface
    Giustini, G.
    Kim, Iljin
    Kim, Hyungdae
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148 (148)
  • [32] Response to Letter Regarding Article, "Hands-On Defibrillation: An Analysis of Electrical Current Flow Through Rescuers in Direct Contact With Patients During Biphasic External Defibrillation"
    Lloyd, Michael S.
    Heeke, Brian
    Walter, Paul F.
    Langberg, Jonathan J.
    CIRCULATION, 2008, 118 (23) : E713 - E713
  • [33] Letter by Sullivan Regarding Article, "Hands-On Defibrillation: An Analysis of Electrical Current Flow Through Rescuers in Direct Contact With Patients During Biphasic External Defibrillation"
    Sullivan, Joseph L.
    CIRCULATION, 2008, 118 (23) : E712 - E712
  • [34] COMPARISON OF ELECTRICAL-IMPEDANCE AND THERMAL DILUTION MEASURED CARDIAC-OUTPUT IN THE CRITICAL CARE SETTING
    JUDY, WV
    POWNER, DJ
    PARR, K
    DEMETER, R
    BATES, C
    MARSHALL, S
    CRITICAL CARE MEDICINE, 1985, 13 (04) : 305 - 305
  • [35] Comparison of dynamic changes in aortic diameter during the cardiac cycle measured by computed tomography angiography and transthoracic echocardiography
    Huang, Jian
    Wang, Yongsheng
    Lin, Lin
    Li, Zhibin
    Shan, Zhonggui
    Zheng, Shaoyi
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (05) : 1538 - 1544
  • [36] Impedance compensated biphasic waveforms for transthoracic cardioversion of atrial fibrillation: a multi-centre comparison of antero-apical and antero-posterior pad positions
    Walsh, SJ
    McCarty, D
    McClelland, AJJ
    Owens, CG
    Trouton, TG
    Harbinson, MT
    O'Mullan, S
    McAllister, A
    McClements, BM
    Stevenson, M
    Dalzell, GWN
    Adgey, AAJ
    EUROPEAN HEART JOURNAL, 2005, 26 (13) : 1298 - 1302
  • [37] CHANGES IN TRANSTHORACIC ELECTRICAL IMPEDANCE DURING SUBMAXIMAL TREADMILL EXERCISE IN PATIENTS WITH ISCHEMIC HEART-DISEASE - PRELIMINARY-REPORT
    BALASUBRAMANIAN, V
    HOON, RS
    AMERICAN HEART JOURNAL, 1976, 91 (01) : 43 - 49
  • [38] Regional Lung Perfusion Measured By Electrical Impedance Tomography - A Comparison Of The Bolus Contrast And Frequency-Filtering Approaches
    Elke, G.
    Hintze, C.
    Meybohm, P.
    Biederer, J.
    Weiler, N.
    Frerichs, I.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [39] Comparison of electrical impedance tomography and intracranial pressure during dehydration treatment of cerebral edema
    Yang, Bin
    Li, Bing
    Xu, Canhua
    Hu, Shijie
    Dai, Meng
    Xia, Junying
    Luo, Peng
    Shi, Xuetao
    Zhao, Zhanqi
    Dong, Xiuzhen
    Fei, Zhou
    Fu, Feng
    NEUROIMAGE-CLINICAL, 2019, 23
  • [40] Regional ventilation redistribution measured by electrical impedance tomography during spontaneous breathing trial with automatic tube compensation
    Hsu, Yeong-Long
    Tien, Ai-Jia
    Chang, Mei-Yun
    Chang, Hao-Tai
    Moeller, Knut
    Frerichs, Inez
    Zhao, Zhanqi
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (06) : 1193 - 1203