Optimization of dialysate flow in on-line hemodiafiltration

被引:8
|
作者
Maduell, Francisco [1 ]
Ojeda, Raquel [1 ]
Arias-Guillen, Marta [1 ]
Fontsere, Nestor [1 ]
Vera, Manel [1 ]
Masso, Elisabeth [1 ]
Gomez, Miguel [1 ]
Rodas, Lida [1 ]
Bazan, Giannina [1 ]
Jimenez-Hernandez, Mario [1 ]
Pineiro, Gaston [1 ]
Rico, Nayra [2 ]
机构
[1] Hosp Clin Barcelona, Dept Nefrol & Trasplante Renal, E-08036 Barcelona, Spain
[2] Hosp Clin Barcelona, Dept Bioquim, E-08036 Barcelona, Spain
来源
NEFROLOGIA | 2015年 / 35卷 / 05期
关键词
Dialysate flow; On-line hemodiafiltration; Efficacy; Convective volume; TRANSFER-AREA COEFFICIENTS; ALL-CAUSE MORTALITY; MASS-TRANSFER; CONVECTIVE VOLUME; CLINICAL-EVIDENCE; HEMODIALYSIS; UREA; EFFICIENCY; DIALYZER; RATES;
D O I
10.1016/j.nefro.2015.06.019
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Currently, on-line hemodiafiltration (HDF-OL) is the most effective technique. Several randomized studies and meta-analyses have shown a reduced mortality and a direct association with convective volume has been reported. At present, it has not been established if an increased dialysate flow (Qd) results in improved results in terms of convective and depurative efficiency. We aim at assessing the effects of Qd variations on convective volume and its depurative capacity in patients on HDF-OL. Material and methods: A total of 59 patients (45 men and 14 women) from a HDF-OL programme in which a monitor 5008 Cordiax with self-replacement was used, were enrolled. Patients were assessed in 5 sessions with post-dilutional HDF-OL, using helixone-based dialyzers, with only Qd being changed (300, 400, 500, 600 and 700 ml/min). Serum levels of urea (60 Da), creatinine (113 Da),beta(2)-microglobulin (11,800 Da), myoglobin (17,200 Da) and alpha(1)-microglobulin (33,000 Da) were measured at the beginning and at the end of each session, in order to estimate the percent reduction of such solutes. Results: An increased dialysate volume per session was observed, from 117.9 +/- 6.4 L with Qd 300 ml/min to 232.4 +/- 12 L with Qd 700 ml/min. No changes were found in replacement volume or convective volume. Regarding diffusion, Qd increase was associated to a significantly increased dialysis dose, with an increased Kt from 68 +/- 6.9 L with Qd 300 ml/min to 75.5 +/- 7.3 L with Qd 700 ml/min (p < 0,001), and a gradually increased percent reduction in urea associated to increased Qd with significantly lower levels being found with Qd 300 ml/min. No changes were found in other measured substances. Conclusion: Qd variations in HDF-OL do not change convective volume. A higher Qd was associated to a slightly increased urea clearance with no change being observed for medium and large molecules. Qd optimisation to the minimal level assuring an adequate dialysis dose and allowing water and dialysate use to be rationalised should be recommended. (C) 2015 The Authors. Published by Elsevier Espana, S.L.U. on behalf of Sociedad Espanola de Nefrologia.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [31] Sustainability and environmental impact of on-line hemodiafiltration
    Chazot, Charles
    SEMINARS IN DIALYSIS, 2022, 35 (05) : 446 - 448
  • [32] Diafilters for Predilution and Postdilution On-Line Hemodiafiltration
    Yamashita, Akihiro C.
    BLOOD PURIFICATION, 2013, 35 : 29 - 33
  • [33] Optimization flow control with on-line measurement
    Low, SH
    TELETRAFFIC ENGINEERING IN A COMPETITIVE WORLD, 1999, 3 : 237 - 249
  • [34] Hemodiafiltration Using Pre-dilutional On-line Citrate Dialysate: A New Technique for Regional Citrate Anticoagulation: A Feasibility Study
    Bousselmi, Radhouane
    Baffoun, Anis
    Hajjej, Zied
    Ben Saleh, Mohamed
    Labbene, Iheb
    Ferjani, Mustapha
    Hmida, Mohamed Jalel
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2015, 26 (04) : 739 - 742
  • [35] Stress oxidative analysis in patients on hemodiafiltration on-line
    Torregrosa, E.
    Hernandez Jaras, J.
    Sastre, J.
    Pons, R.
    Garcia Calvo, H.
    Calvo Gordo, C.
    Fenollosa, M. A.
    Rius, A.
    Sanchez-Canel, J. J.
    Pin, M.
    Tamarit, E.
    Rico, I.
    NEFROLOGIA, 2007, 27 (05): : 612 - 618
  • [36] On-line hemodiafiltration技术和临床应用
    谢红浪
    季大玺
    肾脏病与透析肾移植杂志, 2005, (04) : 377 - 381
  • [37] Achieving High Convective Volumes in On-Line Hemodiafiltration
    Bowry, Sudhir K.
    Canaud, Bernard
    BLOOD PURIFICATION, 2013, 35 : 23 - 28
  • [38] On-line hemodiafiltration in a small dialysis facility.
    Finch, CD
    Finch, JC
    Graves, BE
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A0744 - A0744
  • [39] IONIC DIALYSANCE AND UREA CLEARANCE IN ON-LINE HEMODIAFILTRATION
    Bourry, E.
    Churlaud, G.
    Bismut, F. H.
    Petitclerc, T.
    Venditto, M.
    Szumilak, D.
    Hacini, S.
    Deray, G.
    Mercadal, L.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 405 - 406
  • [40] Evidence for the Clinical Advantages of Predilution On-Line Hemodiafiltration
    Masakane, Ikuto
    Kikuchi, Kan
    Kawanishi, Hideki
    SCIENTIFIC ASPECTS OF DIALYSIS THERAPY: JSDT/ISBP ANNIVERSARY EDITION, 2017, 189 : 17 - 23