Optimization model of submerged hollow fiber membrane modules

被引:55
|
作者
Yoon, SH [1 ]
Kim, HS
Yeom, IT
机构
[1] Nalco Co, Global Res Ctr, Naperville, IL 60563 USA
[2] Sungkyunkwan Univ, Dept Civil Engn, Suwon 440746, South Korea
关键词
modules; economics; water treatment; submerged membrane;
D O I
10.1016/j.memsci.2004.01.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A practical method to obtain optimum design parameters of vertically mounted submerged hollow fiber module was demonstrated to minimize the energy consumption for aeration. Assuming maximum allowable pressure difference in both ends of hollow fiber membrane was 5%, maximum allowable fiber length was calculated for various fluxes and fiber diameters. In case there was no limitation in fiber length, permeate throughput from unit footprint simply increased with fiber diameter. However, if there was a limitation in fiber length/water depth, optimum range of fiber length and lumen diameter existed. For one-side suction, optimum range of outer fiber diameter and fiber length were estimated to be 2.26-3.25 turn and 1.01-1.90 in, respectively, when operating flux was 20-501/m(2) h and a ratio of lumen and outer diameter was 1:2. In the case of two-side suction, fiber length of 1.01-1.90 m and diameter of 1.34-2.05 mm were the optimum range. Finally, optimum design lines, showing the best combinations of lumen diameter and fiber length, were obtained for one-side and two-side suctions. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
  • [31] Numerical analysis of membrane distillation using hollow fiber membrane modules: a review
    Kim, Young Mi
    Guo, Hong
    Seo, Jangwon
    Park, You In
    Kim, Joon Ha
    DESALINATION AND WATER TREATMENT, 2019, 155 : 364 - 369
  • [32] Application of submerged hollow fiber membrane in membrane bioreactors: Filtration principles, operation, and membrane fouling
    Chang, Sheng
    DESALINATION, 2011, 283 : 31 - 39
  • [33] Osmotic-pressure model with permeability analysis for ultrafiltration in hollow-fiber membrane modules
    Yeh, Ho-Ming
    Cheng, Tung-Wen
    Separations Technology, 1993, 3 (02): : 91 - 98
  • [34] A computational fluid dynamics model to predict performance of hollow fiber membrane modules in forward osmosis
    Ren J.
    Chowdhury M.R.
    Xia L.
    Ma C.
    Bollas G.M.
    McCutcheon J.R.
    Journal of Membrane Science, 2021, 603
  • [35] Treatment of submerged hollow fiber ultrafiltration membrane for reuse of sludge water
    School of Civil and Architecture Engineering, Beijing Jiaotong University, Beijing 100044, China
    J. Harbin Inst. Technol., 2008, 2 (183-187):
  • [36] Modeling submerged hollow-fiber membrane filtration for wastewater treatment
    Busch, Jan
    Cruse, Andreas
    Marquardt, Wolfgang
    JOURNAL OF MEMBRANE SCIENCE, 2007, 288 (1-2) : 94 - 111
  • [37] A computational fluid dynamics model to predict performance of hollow fiber membrane modules in forward osmosis
    Ren, Jian
    Chowdhury, Maqsud R.
    Xia, Lingling
    Ma, Cong
    Bollas, George M.
    McCutcheon, Jeffrey R.
    JOURNAL OF MEMBRANE SCIENCE, 2020, 603
  • [38] Distribution of surface shear forces and bubble characteristics in full-scale gas sparged submerged hollow fiber membrane modules
    Fulton, B. G.
    Redwood, J.
    Tourais, M.
    Berube, P. R.
    DESALINATION, 2011, 281 : 128 - 141
  • [39] Fouling control in activated sludge submerged hollow fiber membrane bioreactors
    Hong, SP
    Bae, TH
    Tak, TM
    Hong, S
    Randall, A
    DESALINATION, 2002, 143 (03) : 219 - 228
  • [40] Treatment of submerged hollow fiber ultrafiltration membrane for reuse of sludge water
    姚宏
    单文广
    孙明东
    王晓爽
    Journal of Harbin Institute of Technology, 2008, (02) : 183 - 187