Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

被引:13
|
作者
Tognetto, Daniele [1 ]
Pastore, Marco R. [1 ]
De Giacinto, Chiara [1 ]
Merli, Riccardo [1 ]
Franzon, Marco [2 ]
D'Aloisio, Rossella [1 ]
Belfanti, Lorenzo [1 ]
Giglio, Rosa [1 ]
Cirigliano, Gabriella [1 ]
机构
[1] Univ Trieste, Dept Med Surg Sci & Hlth, Eye Clin, I-34129 Trieste, Italy
[2] Univ Trieste, Dept Math & Comp Sci, I-34129 Trieste, Italy
关键词
MORPHOLOGY; DEVICE; EYES;
D O I
10.1038/s41598-019-46243-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910
  • [22] OcularBiometric Characteristics Measured by Swept-Source Optical Coherence Tomography in Individuals Undergoing Cataract Surgery
    Wasser, Lauren M.
    Tsessler, Maria
    Weill, Yishay
    Zadok, David
    Abulafia, Adi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 38 - 47
  • [23] Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography
    Chen, Minjie
    Hu, Hailin
    He, Wenwen
    Lu, Yi
    Zhu, Xiangjia
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (08) : 1837 - 1844
  • [24] Observation of anterior chamber volume after cataract surgery with swept-source optical coherence tomography
    Minjie Chen
    Hailin Hu
    Wenwen He
    Yi Lu
    Xiangjia Zhu
    International Ophthalmology, 2019, 39 : 1837 - 1844
  • [25] Macular Choroidal Thickening in Keratoconus Patients: Swept-Source Optical Coherence Tomography Study
    Gutierrez-Bonet, Rosa
    Ruiz-Medrano, Jorge
    Pena-Garcia, Pablo
    Catanese, Muriel
    Sadeghi, Yalda
    Hashemi, Katayoon
    Gabison, Eric
    Ruiz-Moreno, Jose M.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (03):
  • [26] Comparison of a new swept-source optical biometer with a partial coherence interferometry
    Hyo Kyung Lee
    Mee Kum Kim
    BMC Ophthalmology, 18
  • [27] Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
    Higashiyama, Tomoaki
    Iwasa, Maki
    Ohji, Masahito
    PLOS ONE, 2017, 12 (08):
  • [28] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Bao Shu
    Fangjun Bao
    Giacomo Savini
    Weicong Lu
    Ruixue Tu
    Haisi Chen
    Benhao Song
    Qinmei Wang
    Jinhai Huang
    Eye and Vision, 7
  • [29] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Shu, Bao
    Bao, Fangjun
    Savini, Giacomo
    Lu, Weicong
    Tu, Ruixue
    Chen, Haisi
    Song, Benhao
    Wang, Qinmei
    Huang, Jinhai
    EYE AND VISION, 2020, 7 (01)
  • [30] Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography
    De Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)