Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imaging

被引:3
|
作者
Leva, Lucia [1 ]
Matheoud, Roberta [2 ]
Sacchetti, Gianmauro [1 ]
Carriero, Alessandro [3 ]
Brambilla, Marco [2 ]
机构
[1] Univ Hosp Maggiore della Carita, Dept Nucl Med, Novara, Italy
[2] Univ Hosp Maggiore della Carita, Dept Med Phys, Novara, Italy
[3] Univ Hosp Maggiore della Carita, Dept Radiol, Novara, Italy
关键词
CAD; gated SPECT; instrumentation; perfusion agents; statistical analysis; ITERATIVE RECONSTRUCTION ALGORITHMS; MYOCARDIAL-PERFUSION SPECT; RESOLUTION RECOVERY; VOLUME MEASUREMENTS; VALIDATION; SYSTEM; QUANTIFICATION; ASSOCIATION; ACQUISITION; PARAMETERS;
D O I
10.1007/s12350-018-1457-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. Methods Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. Results In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. Conclusions The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.
引用
收藏
页码:1714 / 1724
页数:11
相关论文
共 50 条
  • [41] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Wang, Feng
    Zhang, Jian
    Fang, Wei
    Zhao, Shi-Hua
    Lu, Min-Jie
    He, Zuo-Xiang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (10) : 1611 - 1621
  • [42] Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes
    Demir, Hakan
    Tan, Yusuf Z.
    Kozdag, Guliz
    Isgoren, Serkan
    Anik, Yonca
    Ural, Dilek
    Demirci, Ali
    Berk, Fatma
    ANNALS OF SAUDI MEDICINE, 2008, 27 (06) : 415 - 420
  • [43] Left ventricular ejection fraction from gated SPECT thallium imaging: Comparable to RNA and superior to cardiac cath
    Pippin, JJ
    Payne, TD
    Nemec, JJ
    Branstetter, CJ
    Ross, AD
    Devers, SM
    Carr, CM
    Durham, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 98529 - 98529
  • [44] Myocardial perfusion imaging parameters: IQ-SPECT and conventional SPET system comparison
    Havel, Martin
    Kolacek, Michel
    Kaminek, Milan
    Dedek, Vladimir
    Kraft, Otakar
    Sirucek, Pavel
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2014, 17 (03): : 200 - 203
  • [45] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Serge D. Van Kriekinge
    Daniel S. Berman
    Guido Germano
    Journal of Nuclear Cardiology, 1999, 6 : 498 - 506
  • [46] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Van Kriekinge, SD
    Berman, DS
    Germano, G
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (05) : 498 - 506
  • [47] Factors affecting left ventricular ejection fraction using automated quantitative gated SPECT
    Gayed, I
    Cid, E
    Boccalandero, F
    Podoloff, D
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (04) : 290 - 295
  • [48] Quantitative gated SPECT: The effect of filtering on left ventricular ejection fraction measurements.
    Wright, GA
    McDade, M
    Martin, W
    Hutton, I
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 94P - 94P
  • [49] Comparison of left ventricular volumes and ejection fraction between stress and rest gated perfusion SPECT in patients with ischemic heart disease
    Lee, J
    Ahn, BC
    Lee, SW
    Lee, KB
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1234 - 1234
  • [50] Validation of an automated methodology for determining left ventricular ejection fraction from gated SPECT
    Vansant, JP
    Faber, TL
    Folks, RD
    Nichols, K
    DePuey, G
    Garcia, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 98549 - 98549