The quality of intrapartum fetal heart rate monitoring

被引:49
|
作者
Bakker, PCAM [1 ]
Colenbrander, GJ [1 ]
Verstraeten, AA [1 ]
Van Geijn, HP [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Med, Dept Obstet & Gynecol, NL-1007 MB Amsterdam, Netherlands
关键词
fetal heart rate; cardiotocographs; signal loss;
D O I
10.1016/j.ejogrb.2004.01.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the quality of fetal heart rate (FHR) recordings during the first and second stage of labor by quantifying the amount of fetal signal loss in relation to the method of monitoring: external ultrasound or directly via a scalp electrode. Study Design: Analysis of 239 intrapartum recordings stored between I January 2001 and I July 2001 from consecutive deliveries at the Vrije Universiteit Medical Center in Amsterdam. Singletons delivered via the vaginal route were included in the study. FHR recordings had duration of at least I It prior to birth of the infant. Subdivision in three groups took place on the basis of the recording technique which had been used; i.e. ultrasound, scalp electrode or a combination of both methods. FHR data was obtained using HP-M1350 cardiotocographs. The status (pen on, pen off, maternal signal) and the mode of the signals were acquired. The duration of pen lifts and maternal signals was divided by the total duration of the recording. Statistical analyses were performed with the Mann-Whitney U-test and the Wilcoxon signed ranks test. Results: Recordings obtained via ultrasound demonstrated significantly more fetal signal loss than those obtained via the direct mode, particularly in the second stage. The FIGO criteria for fetal signal loss with external ultrasound were not fulfilled during this stage for about half the cases. Conclusion: Intrapartum FHR monitoring via a scalp electrode provides far better quality FHR signals than external ultrasound and deserves a more prominent position in fetal surveillance than it currently has. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [41] Bayesian interpretation of trials: the example of intrapartum electronic fetal heart rate monitoring
    Hornbuckle, J
    Vail, A
    Abrams, KR
    Thornton, JG
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (01): : 3 - 10
  • [42] The Incidence of Maternal Artefact During Intrapartum Fetal Heart Rate Monitoring Response
    Paquette, Stephanie
    Ferraro, Zachary M.
    Oppenheimer, Lawrence
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2015, 37 (03) : 206 - 206
  • [43] UNUSUAL COMPLICATION OF INTRAPARTUM FETAL HEART MONITORING
    CHARTERS, DW
    ABDULLA, U
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1975, 15 (03): : 183 - 185
  • [44] Intrapartum fetal heart rate pattern in oligohydramnios
    Hasegawa, Junichi
    Matsuoka, Ryu
    Ichizuka, Kiyotake
    Kotani, Mihoko
    Ohmori, Azumi
    Nakamura, Masamitsu
    Sekizawa, Akihiko
    Okai, Takashi
    FETAL DIAGNOSIS AND THERAPY, 2008, 24 (03) : 267 - 270
  • [45] INTRAPARTUM AUSCULTATION OF THE FETAL HEART-RATE
    STRONG, TH
    JARLES, DL
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 168 (03) : 935 - 936
  • [46] Interventions for Intrapartum Fetal Heart Rate Abnormalities
    Eller, Alexandra G.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2020, 63 (03): : 635 - 644
  • [49] iPREFACE score: Integrated score index to predict fetal acidemia by intrapartum fetal heart rate monitoring
    Ito, Ayumu
    Hayata, Eijiro
    Nakata, Masahiko
    Oji, Ayako
    Furukawa, Takamasa
    Nakakuma, Masahito
    Morita, Mineto
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2021, 47 (04) : 1305 - 1311
  • [50] Intrapartum fetal pulse oximetry and fetal heart rate decelerations
    Puertas, A
    Navarro, M
    Velasco, R
    Montoya, E
    Miranda, JA
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 (01) : 12 - 17