Sound absorption deviation measured using pressure-velocity sensors by ensemble averaging technique under different relative humidity conditions

被引:3
|
作者
Otsuru, Toru [1 ]
Tomiku, Reiji [1 ]
Okamoto, Noriko [2 ]
Yamauchi, Saki [3 ]
机构
[1] Oita Univ, Fac Engn, 700 Dannoharu, Oita 8701192, Japan
[2] Univ Kitakyushu, Fac Environm Engn, 1-1 Hibikino, Kitakyushu, Fukuoka 8701192, Japan
[3] Oita Univ, Grad Sch, 700 Dannoharu, Oita 8701192, Japan
关键词
Sound absorption measurement; Pressure-velocity sensor; Calibration; Relative humidity; SURFACE NORMAL IMPEDANCE; IN-SITU TECHNIQUE;
D O I
10.1016/j.apacoust.2017.02.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, measurements using pressure-velocity sensors (pu-sensor) have come to be important in various fields of acoustics. Insufficient data exist to assure the accuracy and stability of results from measurements obtained using a pu-sensor. Herein, deviations found in the resulting absorption coefficients measured using pu-sensors were examined in relation to differences in relative humidity at the time of calibration and those at the time of absorption measurements. A series of sound absorption measurements using pu-sensors was conducted in a reverberation room under humidity control using an ensemble averaging technique proposed in reports of the authors' earlier studies. Three pu-sensors having the same specifications were used for comparison. Measurements were taken of three porous materials: both absorptive and less absorptive. Then pu-sensors were calibrated using a standing-wave-tube (SWT). Both the materials and SWT were put inside the reverberation room for more than half a day to maintain inside humidity as approximately equivalent to room conditions. The relative humidity inside the reverberation room was controlled to 40-70%. Results show that certain fluctuations occur in the amplitudes of calibration values of pressure sensors and in those of velocity sensors when the relative humidity varies from 40% to 70%: Moreover, if the difference of humidity between that at calibration and that at the time of measurement is maintained within 8%, then sound absorption can be measured stably with less deviation. The issues presented herein provide specific guidelines not only for absorption measurements but also for various applications of pu-sensors. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 12 条
  • [11] CO2 Measurement under Different Pressure and Vibration Conditions Using Tunable Diode Laser Absorption Spectroscopy
    Ban, Deyue
    Li, Nan
    Zheng, Yongqiu
    Xue, Chenyang
    PHOTONICS, 2024, 11 (02)
  • [12] Sound velocity and density of liquid Ni68S32 under pressure using ultrasonic and X-ray absorption with tomography methods
    Terasaki, Hidenori
    Nishida, Keisuke
    Urakawa, Satoru
    Takubo, Yusaku
    Kuwabara, Soma
    Shimoyama, Yuta
    Uesugi, Kentaro
    Kono, Yoshio
    Takeuchi, Akihisa
    Suzuki, Yoshio
    Higo, Yuji
    Kondo, Tadashi
    COMPTES RENDUS GEOSCIENCE, 2019, 351 (2-3) : 163 - 170