Vibration Characteristic of High-Voltage Tower Influenced by Adjacent Tunnel Blasting Construction

被引:16
|
作者
Duan, Limin [1 ]
Lin, Wenshuai [1 ]
Lai, Jinxing [1 ]
Zhang, Peng [2 ]
Luo, Yanbin [1 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
[2] China Railway First Survey & Design Inst Grp Co L, State Key Lab Rail Transit Engn Informatizat, Xian 710043, Shaanxi, Peoples R China
关键词
1is work was financially supported by the National Key R&D program of China (no. 2018YFC0808706) and the Project on Social Development of Shaanxi Provincial Science and Technology Department (nos. 2018SF-382 and 2018SF-378);
D O I
10.1155/2019/8520564
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effects of tunnel blast excavation on the adjacent existing high-voltage tower are comprehensively studied for the Chashan highway tunnel project as a case study. To investigate the effect of blast-induced vibration from the tunnel on the adjacent existing tower, field tests and numerical simulations method were adopted to study the vibration velocity and vibration frequency of the existing tower. Moreover, the relationship between the transverse distance from the detonation center and the peak velocity is discussed in detail. The results showed that the peak velocity of the measuring point in tower foundation increases with the distance between the detonation center and tower foundation approaches, and the maximum velocity is appearing when detonation center is 0m. Furthermore, the corresponding energy spectrum distributions of the existing tower under the effect of blast induced by vibration is also analyzed, and the main frequency of vertical vibration is generally higher than that of transverse vibration. On combining the peak velocity with the main frequency and the natural frequency of the tower, the safety evaluation of the blasting area is proposed, and the corresponding control measures of blasting vibration are put forward. A guideline for the blast safety zone is proposed based on vibration velocity, main frequency, and the quantity of explosive.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Test and analysis of an existing tunnel vibration induced by blasting construction of diaphragm wall
    Yu G.
    Yu H.
    Liu X.
    Yuan Y.
    Wang Q.
    Cheng G.
    Wu X.
    Transactions of Tianjin University, 2008, 14 (SUPPL.): : 569 - 575
  • [42] Theoretical study of the vibration characteristic in geological layer under blasting excavation of metro tunnel
    Zhang, Zhen
    Yao, Yingkang
    Jiang, Nan
    Xie, Quanmin
    Wang, Junhao
    JOURNAL OF VIBRATION AND CONTROL, 2024,
  • [43] The monitoring technology research about the tunnel blasting vibration under the complex construction
    Zhao, Jiangqian
    Ju, Haiyan
    Li, Jianhua
    Liu, Youping
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1078 - 1081
  • [44] Test and Analysis of an Existing Tunnel Vibration Induced by Blasting Construction of Diaphragm Wall
    于光喜
    禹海涛
    柳献
    袁勇
    王庆国
    程国荣
    吴晓峰
    Transactions of Tianjin University, 2008, (S1) : 569 - 575
  • [45] Study on Vibration Laws of Ground Particles Cause by Shallow Tunnel Blasting Construction
    Wang Juntao
    Yang Qing
    Wang Hailiang
    CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 1420 - +
  • [46] Analysis of factors influencing vibration reduction and design optimization of damping holes in adjacent tunnel blasting
    Guan, Xiaoming
    Yao, Yingkang
    Yang, Ning
    Xu, Huawei
    Xin, Baicheng
    Li, Bingyu
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [47] Wind tunnel test on wind resistant design of high-voltage transmission tower-line coupling system
    Zhao, Gui-Feng
    Xie, Qiang
    Liang, Shu-Guo
    Li, Jie
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (05): : 1206 - 1213
  • [48] Wind tunnel test and response analysis of high-voltage transmission tower subjected to combined loads of wind and rain
    Fu, Xing
    Lin, You-Xin
    Li, Hong-Nan
    Gongcheng Lixue/Engineering Mechanics, 2014, 31 (01): : 72 - 78
  • [49] Finite Element Model Of High-voltage Transmission Tower Confirmed
    Liu, Chuncheng
    Xu, Qiangsheng
    APPLIED MECHANICS AND MECHANICAL ENGINEERING IV, 2014, 459 : 625 - 630
  • [50] Effect of wind-induced vibration's control for high-voltage transmission tower based on prototype measurement
    Wang, W. (wangwei@gddky.csg.cn), 1600, Central South University of Technology (44):