共 50 条
Thermal modelling of N partially covered photovoltaic thermal (PVT) - Compound parabolic concentrator (CPC) collectors connected in series
被引:78
|作者:
Tripathi, Rohit
[1
]
Tiwari, G. N.
[1
]
Al-Helal, I. M.
[2
]
机构:
[1] Indian Inst Technol Delhi, Ctr Energy Studies, New Delhi 110016, India
[2] King Saud Univ, Dept Agr Engn, Coll Food & Agr Sci, Riyadh 11451, Saudi Arabia
来源:
关键词:
PVT water collector;
Compound parabolic concentrator;
Characteristic equation;
SOLAR AIR HEATER;
PERFORMANCE ANALYSIS;
SYSTEM;
D O I:
10.1016/j.solener.2015.11.014
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
In the present study, the thermal energy balance equations have been taken for N partially covered photovoltaic thermal compound parabolic concentrator collectors (N-PVT-CPC) connected in series. An analytical mathematical expression for Nth outlet water temperature (T-foN) and efficiency of solar cell at Nth collector (eta(cN)) have been derived in terms of climate and design parameters. Numerical computations have been carried out for two Indian climatic condition namely (a) January (winter) and (b) June (summer), respectively. Effect of number of PVT-CPC collectors connected in series, mass flow rate and the percentage of PV coverage on various temperatures, an overall thermal energy and overall exergy have been carried. It has been observed that an overall exergy of proposed system is maximum for winter condition due to less thermal losses. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:174 / 184
页数:11
相关论文