Improving the Voltammetric Determination of Hg(II): A Comparison Between Ligand-Modified Glassy Carbon and Electrochemically Reduced Graphene Oxide Electrodes

被引:5
|
作者
Raicopol, Matei D. [1 ]
Pandele, Andreea M. [1 ]
Dascalu, Constanta [2 ]
Vasile, Eugeniu [1 ]
Hanganu, Anamaria [3 ]
Vasile, Gabriela-Geanina [4 ]
Bugean, Ioana Georgiana [1 ]
Pirvu, Cristian [1 ]
Stanciu, Gabriela [5 ]
Buica, George-Octavian [1 ]
机构
[1] Univ Politehn Bucuresti, Fac Appl Chem & Mat Sci, 1-7 Gheorghe Polizu St, Bucharest 011061, Romania
[2] Univ Politehn Bucuresti, Fac Appl Sci, 313 Splaiul Independentei, Bucharest 060042, Romania
[3] Univ Bucharest, Dept Organ Chem Biochem & Catalysis, 90-92 Sos Panduri, Bucharest 050657, Romania
[4] Natl Res & Dev Inst Ind Ecol ECOIND Bucharest, 71-73 Drumul Podul Dambovitei St, Bucharest 060652, Romania
[5] Ovidius Univ, Dept Chem & Chem Engn, 124 Mamaia Blvd, Constanta 900527, Romania
关键词
modified electrodes; electrochemically reduced graphene oxide; thiosemicarbazone; click chemistry; anodic stripping voltammetry; mercury determination;
D O I
10.3390/s20236799
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new thiosemicarbazone ligand was immobilized through a Cu(I)-catalyzed click reaction on the surface of glassy carbon (GC) and electrochemically reduced graphene oxide (GC-ERGO) electrodes grafted with phenylethynyl groups. Using the accumulation at open circuit followed by anodic stripping voltammetry, the modified electrodes showed a significant selectivity and sensibility for Hg(II) ions. A detection limit of 7 nM was achieved with the GC modified electrodes. Remarkably, GC-ERGO modified electrodes showed a significantly improved detection limit (0.8 nM), sensitivity, and linear range, which we attribute to an increased number of surface binding sites and better electron transfer properties. Both GC and GC-ERGO modified electrodes proved their applicability for the analysis of real water samples.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 50 条
  • [41] A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A
    Qin, Jingyu
    Shen, Jing
    Xu, Xiangyang
    Yuan, Yuan
    He, Guangyu
    Chen, Haiqun
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [42] Differential Pulse Voltammetric Determination of Folic Acid in the Presence of Ascorbic Acid using A Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Abd-Elsabour, Mohamed
    Toghan, Arafat
    Abo-bakr, Ahmed M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 789 - 805
  • [43] A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A
    Jingyu Qin
    Jing Shen
    Xiangyang Xu
    Yuan Yuan
    Guangyu He
    Haiqun Chen
    Microchimica Acta, 2018, 185
  • [44] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Palanisamy, Selvakumar
    Ramaraj, Sayee Kannan
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Yang, Thomas C. K.
    Chen, Tse-Wei
    MICROCHIMICA ACTA, 2017, 184 (04) : 1051 - 1057
  • [45] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    Microchimica Acta, 2017, 184 : 1051 - 1057
  • [46] Voltammetric determination of atenolol at C60-modified glassy carbon electrodes
    Goyal, Rajendra N.
    Singh, Sudhanshu P.
    TALANTA, 2006, 69 (04) : 932 - 937
  • [47] A voltammetric sensor based on electrochemically reduced graphene modified electrode for sensitive determination of midecamycin
    Xi, Xia
    Ming, Liang
    ANALYTICAL METHODS, 2012, 4 (09) : 3013 - 3018
  • [48] Determination of nitrite in tap water: A comparative study between cerium, titanium and selenium dioxide doped reduced graphene oxide modified glassy carbon electrodes
    Stankovic, Dalibor M.
    Mehmeti, Eda
    Zavasnik, Janez
    Kalcher, Kurt
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 311 - 317
  • [49] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200
  • [50] Voltammetric determination of caffeic acid by using a glassy carbon electrode modified with a chitosan-protected nanohybrid composed of carbon black and reduced graphene oxide
    Kannaiyan Pandian
    Dhamodaran Mohana Soundari
    Panneerselvam Rudra Showdri
    Jayaprakash Kalaiyarasi
    Subash C. B. Gopinath
    Microchimica Acta, 2019, 186