The size-dependent efficacy and biocompatibility of hyperbranched polyglycerol in peritoneal dialysis

被引:39
|
作者
Du, Caigan [1 ]
Mendelson, Asher A. [2 ]
Guan, Qiunong [1 ]
Chapanian, Rafi [3 ]
Chafeeva, Irina [3 ]
da Roza, Gerald [2 ]
Kizhakkedathu, Jayachandran N. [3 ,4 ]
机构
[1] Univ British Columbia, Dept Urol Sci, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Med, Div Nephrol, Vancouver, BC, Canada
[3] Univ British Columbia, Ctr Blood Res, Dept Pathol & Lab Med, Vancouver, BC V5Z 1M9, Canada
[4] Univ British Columbia, Dept Chem, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Peritoneal dialysis; Osmotic agent; Hyperbranched polyglycerols; Biocompatibility; FREE-WATER TRANSPORT; SOLUTE TRANSPORT; MOLECULAR-WEIGHT; MESOTHELIAL CELLS; SIMILAR OUTCOMES; SODIUM REMOVAL; GLUCOSE; MEMBRANE; ULTRAFILTRATION; FLUID;
D O I
10.1016/j.biomaterials.2013.10.076
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glucose is a common osmotic agent for peritoneal dialysis (PD), but has many adverse side effects for patients with end-stage renal disease. Recently, hyperbranched polyglycerol (HPG) has been tested as an alternative osmotic agent for PD. This study was designed to further examine the efficacy and biocompatibility of HPG over a range of different molecular weights. HPGs of varying molecular weights (0.5 kDa, 1 kDa, 3 kDa) were evaluated in a preclinical rodent model of PD. HPG PD solutions were standardized for osmolality and compared directly to conventional glucose-based Physioneal (TM) PD solution (PYS). The efficacy of HPG solutions was measured by their ultrafiltration (UF) capacity, solute removal, and free water transport; biocompatibility was determined in vivo by the histological analysis of the peritoneal membrane and the cell count of detached peritoneal mesothelial cells (PMCs) and neutrophils, and in vitro cytotoxicity to cultured human PMCs. All the different sized HPGs induced higher UF and sodium removal over a sustained period of time (up to 8 h) compared to PYS. Urea removal was significantly higher for 1-3 kDa than PYS, and was similar for 0.5 kDa. Our analyses indicated that the peritoneal membrane exhibited more tolerance to the MPG solutions compared to PYS, evidenced by less submesothelial injury and neutrophil infiltration in vivo, and less cell death in cultured human peritoneal mesothelial cells. Free water transport analysis of HPG indicated that these molecules function as colloids and induce osmosis mainly through capillary small pores. We attribute the differences in the biocompatibility and osmotic activity of different sized HPGs to the differences in the polymer bound water measured by differential scanning calorimetry. These preclinical data indicate that compared to PYS, low MW HPGs (0.5-3 kDa) produces superior fluid and waste removal with better biocompatibility profile, suggesting that they are promising osmotic agents for PD. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1378 / 1389
页数:12
相关论文
共 50 条
  • [21] Physiological approaches to increase biocompatibility of peritoneal dialysis
    Veech, RL
    PERITONEAL DIALYSIS INTERNATIONAL, 1996, 16 (03): : 332 - 332
  • [22] Buffer systems and biocompatibility in peritoneal dialysis - Introduction
    Heimburger, O
    Holmes, C
    Mujais, S
    KIDNEY INTERNATIONAL, 2003, 64 : S1 - S2
  • [23] BIOCOMPATIBILITY IN PERITONEAL-DIALYSIS - DEFINITIONS AND MECHANISMS
    WILLIAMS, JD
    PERITONEAL DIALYSIS INTERNATIONAL, 1995, 15 (07): : S5 - S8
  • [24] The rabbit model in evaluating the biocompatibility in peritoneal dialysis
    Garosi, G
    Di Paolo, N
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (03) : 664 - 665
  • [25] Multidirectional approach to study peritoneal dialysis fluid biocompatibility in a chronic peritoneal dialysis model in the rat
    Wieczorowska-Tobis, K
    Polubinska, A
    Wisniewska, J
    Pawlaczyk, K
    Kuzlan-Pawlaczyk, M
    Filas, V
    Breborowicz, A
    Oreopoulos, DG
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (03) : 655 - 656
  • [26] Peritoneal dialysis fluid biocompatibility impact on human peritoneal membrane permeability
    Rodriguez-Esparragon, Francisco
    Marrero-Robayna, Silvia
    Gonzalez-Cabrera, Fayna
    Hernandez-Trujillo, Yaride
    Buset-Rios, Nisa
    Carlos Rodriguez-Perez, Jose
    Vega-Diaz, Nicanor
    CLINICAL KIDNEY JOURNAL, 2018, 11 (06) : 881 - 888
  • [27] Does the biocompatibility of the peritoneal dialysis solution matter in assessment of peritoneal function?
    Parikova, Alena
    Struijk, Dirk G.
    Zweers, Machteld M.
    Langedijk, Monique
    Schouten, Natalie
    van den Berg, Nicole
    Duis, Saskia
    Krediet, Raymond T.
    PERITONEAL DIALYSIS INTERNATIONAL, 2007, 27 (06): : 691 - 696
  • [28] Size-dependent thermoelasticity
    Hadjesfandiari, Ali R.
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2014, 11 (09): : 1679 - 1708
  • [29] Effects of peritoneal dialysis fluid biocompatibility on baroreflex sensitivity
    John, S. G.
    Selby, N. M.
    McIntyre, C. W.
    KIDNEY INTERNATIONAL, 2008, 73 : S119 - S124
  • [30] PERITONEAL-DIALYSIS SOLUTION BIOCOMPATIBILITY TESTING IN ANIMALS
    DIPAOLO, N
    GAROSI, G
    PETRINI, G
    TRAVERSARI, L
    ROSSI, P
    PERITONEAL DIALYSIS INTERNATIONAL, 1995, 15 (07): : S61 - S70