Embedded steel column-to-foundation connection for a modular structural system
被引:80
|
作者:
Park, Keum-Sung
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South KoreaKorea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
Park, Keum-Sung
[1
]
Moon, Jiho
论文数: 0引用数: 0
h-index: 0
机构:
KRRI, New Transportat Res Ctr, Uiwang Si 437757, Gyeonggi Do, South KoreaKorea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
Moon, Jiho
[2
]
Lee, Sang-Sup
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South KoreaKorea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
Lee, Sang-Sup
[1
]
Bae, Kyu-Woong
论文数: 0引用数: 0
h-index: 0
机构:
Korea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South KoreaKorea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
Bae, Kyu-Woong
[1
]
Roeder, Charles W.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USAKorea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
Roeder, Charles W.
[3
]
机构:
[1] Korea Inst Construct Technol, Adv Bldg Res Div, Goyang Si 411712, Gyeonggi Do, South Korea
[2] KRRI, New Transportat Res Ctr, Uiwang Si 437757, Gyeonggi Do, South Korea
[3] Univ Washington, Dept Civil & Environm Engn, Seattle, WA 98195 USA
Pre-made modular units permit rapid and economical construction and are increasingly used where repetitive units are required. The assembled building must behave as a single structure to effectively transfer the forces and moments developed by gravity and lateral loads. For this, individual modular units must be properly connected to each other. Therefore, evaluation of the behavior of connections used in modular construction is crucial. This study proposes an embedded steel column-to-foundation connection for modular structural systems and evaluates the behavior of the proposed connection. Experiments were performed to investigate the effect of the column embedment depth, the shape of the column end plate, and shear studs in the embedded region of the column on the connection behavior. Further, three dimensional nonlinear finite element analyses were conducted for each test specimen to demonstrate the in-depth behavior of the connection. Finally, a design equation for the proposed connection was proposed. (C) 2015 Elsevier Ltd. All rights reserved.
机构:
Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
Jeyabalan, Aswin Kumar Rajakala
Selvaraj, Sivaganesh Kanmani
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
Selvaraj, Sivaganesh Kanmani
Chan, Tak-Ming
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China