Loop-mediated isothermal amplification (LAMP) test in the detection of uncomplicated malaria in pregnancy: a meta-analysis of diagnostic accuracy

被引:2
|
作者
Yon, Joseph Lee Teck [1 ,2 ]
Htet, Norah Htet [1 ]
Naing, Cho [3 ]
Tung, Wong Siew [1 ]
Aung, Htar Htar [1 ]
Mak, Joon Wah [4 ]
机构
[1] Int Med Univ, Sch Med, Kuala Lumpur, Malaysia
[2] Univ Edinburgh, Old Coll, Edinburgh EH8 9YL, Scotland
[3] James Cook Univ, Div Trop Hlth & Med, Townsville, Qld, Australia
[4] Int Med Univ, Inst Res Dev & Innovat IRDI, Kuala Lumpur, Malaysia
关键词
PERFORMANCE; PCR;
D O I
10.1186/s12936-022-04419-9
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Due to relatively low malaria parasitaemia in pregnancy, an appropriate field test that can adequately detect infections in pregnant women presenting with illness or for malaria screening during antenatal care is crucially important. The objective was to evaluate the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for the detection of uncomplicated malaria in pregnancy. Methods: This was a meta-analysis of diagnostic accuracy. Relevant studies that assessed the diagnostic performance of LAMP for the detection of malaria in pregnancy were searched in health-related electronic databases including PubMed, Ovid, and Google Scholar. The methodological quality of the studies included was evaluated using the QUADAS-2 tool.Results: Of the 372 studies identified, eight studies involving 2999 pregnant women in five endemic countries that assessed the accuracy of LAMP were identified. With three types of PCR as reference tests, the pooled sensitivity of LAMP was 91% (95%CI 67-98%) and pooled specificity was 99% (95%CI 83-100%, 4 studies), and the negative likelihood ratio was 9% (2-40%). Caution is needed in the interpretation as there was substantial between-study heterogeneity (I2: 80%), and a low probability that a person without infection is tested negative. With microscopy as a reference, the pooled sensitivity of LAMP was 95% (95%CI 26-100%) and pooled specificity was 100% (95%CI 94-100%, 4 studies). There was a wide range of sensitivity and substantial between-study heterogeneity (I2: 83.5-98.4%). To investigate the source of heterogeneity, a meta-regression analysis was performed with covariates. Of these potential confounding factors, reference test (p: 0.03) and study design (p:0.03) had affected the diagnostic accuracy of LAMP in malaria in pregnancy. Overall, there was a low certainty of the evidence in accuracy estimates.Conclusion: The findings suggest that LAMP is more sensitive than traditional tests used at facilities, but the utility of detecting and treating these low-density infections is not well understood. Due to the limited number of studies with bias in their methodological quality, variation in the study design, and different types of reference tests further research is likely to change the estimate. Well-conceived large prospective studies with blinding of the index test results are recommenced.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Loop-mediated isothermal amplification test for the molecular diagnosis of malaria
    Han, Eun-Taek
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 205 - 218
  • [22] A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinION™ nanopore sequencer
    Imai, Kazuo
    Tarumoto, Norihito
    Misawa, Kazuhisa
    Runtuwene, Lucky Ronald
    Sakai, Jun
    Hayashida, Kyoko
    Eshita, Yuki
    Maeda, Ryuichiro
    Tuda, Josef
    Murakami, Takashi
    Maesaki, Shigefumi
    Suzuki, Yutaka
    Yamagishi, Junya
    Maeda, Takuya
    BMC INFECTIOUS DISEASES, 2017, 17
  • [23] Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria
    Kollenda, Hans
    Hagen, Ralf Matthias
    Hanke, Miriam
    Rojak, Sandra
    Hinz, Rebecca
    Wassill, Lars
    Poppert, Sven
    Tannich, Egbert
    Frickmann, Hagen
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2018, 8 (04): : 112 - 118
  • [24] A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinION™ nanopore sequencer
    Kazuo Imai
    Norihito Tarumoto
    Kazuhisa Misawa
    Lucky Ronald Runtuwene
    Jun Sakai
    Kyoko Hayashida
    Yuki Eshita
    Ryuichiro Maeda
    Josef Tuda
    Takashi Murakami
    Shigefumi Maesaki
    Yutaka Suzuki
    Junya Yamagishi
    Takuya Maeda
    BMC Infectious Diseases, 17
  • [25] Detection of mink enteritis virus by loop-mediated isothermal amplification (LAMP)
    Wang, Jianke
    Cheng, Shipeng
    Yi, Li
    Cheng, Yuening
    Yang, Shen
    Xu, Hongli
    Li, Zhenguang
    Shi, Xinchuan
    Wu, Hua
    Yan, Xijun
    JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (02) : 401 - 405
  • [26] Development of loop-mediated isothermal amplification (LAMP) for detection of Theileria equi
    Xie, Junren
    Liu, Guangyuan
    Tian, Zhancheng
    Luo, Jin
    ACTA TROPICA, 2013, 127 (03) : 245 - 250
  • [27] Development of Loop-Mediated Isothermal Amplification (LAMP) for Universal Detection of Enteroviruses
    Zhao, Hua-Bing
    Yin, Guang-Ya
    Zhao, Guo-Ping
    Huang, Ai-Hua
    Wang, Jun-Hong
    Yang, Shuang-Feng
    Gao, Hong-Sheng
    Kang, Wei-Jun
    INDIAN JOURNAL OF MICROBIOLOGY, 2014, 54 (01) : 80 - 86
  • [28] Loop-mediated isothermal amplification (LAMP) for the rapid detection of Mycoplasma genitalium
    Edwards, Thomas
    Burke, Patricia
    Smalley, Helen B.
    Gillies, Liz
    Longhurst, Denise
    Vipond, Barry
    Hobbs, Glyn
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 83 (01) : 13 - 17
  • [29] Detection of Kudoa amamiensis Using Loop-Mediated Isothermal Amplification (LAMP)
    Sakai, Masahiro
    Biswas, Gouranga
    Kono, Tomoya
    Hikima, Jun-ichi
    Yokoyama, Hiroshi
    FISH PATHOLOGY, 2015, 50 (03): : 119 - 122
  • [30] Detection of toxigenic Clostridium difficile by Loop-Mediated Isothermal Amplification (LAMP)
    Jayaratne, P.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2014, 21 : 379 - 380