Oscillator microfabrication, micromagnets, and magnetic resonance force microscopy

被引:5
|
作者
Choi, JH [1 ]
Mirsaidov, UM [1 ]
Miller, CW [1 ]
Lee, YJ [1 ]
Guchhait, S [1 ]
Chabot, MD [1 ]
Lu, W [1 ]
Markert, JT [1 ]
机构
[1] Univ Texas, Dept Phys, Austin, TX 78712 USA
关键词
mechanical oscillator; microfabrication; micromagnets; magnetic resonance force microscopy;
D O I
10.1117/12.539572
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report our advances in nuclear magnetic resonance force microscopy (NMRFM) in three areas: 1) MEMS microfabrication studies of single-crystal-silicon mechanical oscillators using double-sided processing; 2) micromagnetometry, anisotropy, and dissipation studies of individual permalloy micromagnets on oscillators; and 3) mechanical-oscillator detection of NMR in the magnet-on-oscillator scanning mode. In the first area, we report details of our back-etch microfabrication process, and characterize oscillator resonant frequency, quality factor, and spring constant by measuring the noise spectral density of oscillator motion. In the second studies, we report changes in the resonant frequency and quality factor for each of four modes of our oscillators for two shapes and sizes of permalloy thin-film (similar to30 and 180 nm) micromagnets; a simple, quantitative model is used to describe both low-field softening and high-field stiffening. Finally, we report scanning-mode NMR force detection of an ammonium-sulfate single-crystal interface and a polymethyl-methyl-acrylate thin film at room temperature. These latter studies use 2-mum-radius permalloy magnets on silicon oscillators to image the NMR response from resonant volumes as small as 3 mum(3). These NMRFM studies are the first reported that attain sub-micron resonant-slice resolution at room temperature.
引用
收藏
页码:399 / 410
页数:12
相关论文
共 50 条
  • [41] Ferromagnetic resonance imaging of Co films using magnetic resonance force microscopy
    Suh, BJ
    Hammel, PC
    Zhang, Z
    Midzor, MM
    Roukes, ML
    Childress, JR
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1998, 16 (04): : 2275 - 2279
  • [42] Observation of ferromagnetic resonance in a microscopic sample using magnetic resonance force microscopy
    Zhang, Z
    Hammel, PC
    Wigen, PE
    APPLIED PHYSICS LETTERS, 1996, 68 (14) : 2005 - 2007
  • [43] Nuclear magnetic resonance force microscopy with a microwire rf source
    Poggio, M.
    Degen, C. L.
    Rettner, C. T.
    Mamin, H. J.
    Rugar, D.
    APPLIED PHYSICS LETTERS, 2007, 90 (26)
  • [44] Force-detected scanned probe magnetic resonance microscopy
    Hammel, PC
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2002, 16 (20-22): : 3378 - 3378
  • [45] Manipulation and detection of electron spins by magnetic resonance force microscopy
    Rugar, D
    Budakian, R
    Mamin, HJ
    Chui, BW
    SCANNING TUNNELING MICROSCOPY/SPECTROSCOPY AND RELATED TECHNIQUES, 2003, 696 : 45 - 52
  • [46] Nonlinear dynamics and stability of a microcantilever for Magnetic Resonance Force Microscopy
    Hacker, Evyatar
    Ruiz-Oliveras, F.
    Gottlieb, Oded
    IEICE NONLINEAR THEORY AND ITS APPLICATIONS, 2013, 4 (03): : 272 - 283
  • [47] Magnetic resonance force microscopy with matching frequencies of cantilever and spin
    Berman, Gennady P.
    Tsifrinovich, Vladimir, I
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (04)
  • [48] A GLRT and bootstrap approach to detection in magnetic resonance force microscopy
    Chung, PJ
    Moura, J
    2004 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL II, PROCEEDINGS: SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING SIGNAL PROCESSING THEORY AND METHODS, 2004, : 1061 - 1064
  • [49] Mechanical modulation of sample magnetization in magnetic resonance force microscopy
    Marohn, JA
    Fainchtein, R
    Smith, DD
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (08) : 4619 - 4625
  • [50] Superconducting microwave resonator for millikelvin magnetic resonance force microscopy
    Mamin, HJ
    Budakian, R
    Rugar, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05): : 2749 - 2753