Voltammetric analysis of weak acids with microelectrodes

被引:20
|
作者
Canhoto, C [1 ]
Matos, M [1 ]
Rodrigues, A [1 ]
Geraldo, MD [1 ]
Bento, MF [1 ]
机构
[1] Univ Minho, Dept Quim, P-4710057 Braga, Portugal
关键词
weak acids analysis; microelectrodes; voltammetry;
D O I
10.1016/j.jelechem.2004.03.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The role of H+ on the steady-state voltammetric limiting current (I-L) of weak acid (HA) reduction was studied considering results from either lactic acid or acetic acid solutions at constant pH. For solutions with pH > pK(a) or pH congruent to pKa the [H+] effect on the I-L vs c(HA) slope was important even when the H+ current contribution was minor. In contrast, when the pH < pK(a) high H+ current contributions were found; nevertheless the I-L VS c(HA) slope was almost insensitive to pH. A general relationship between I-L and c(HA) was derived considering both the H+ current contribution and the dissociation extent. This equation allows the analytical determination of weak acids, alone or in the presence of strong acids, from experimental I-L and pH. Acid identification can also be performed through the expression presented, following the I-L susceptibility to pH at constant c(HA). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 50 条
  • [21] SELF-ENHANCEMENT OF VOLTAMMETRIC WAVES OF WEAK ACIDS IN THE ABSENCE OF SUPPORTING ELECTROLYTE
    STOJEK, Z
    CISZKOWSKA, M
    OSTERYOUNG, JG
    ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1507 - 1512
  • [22] Application of voltammetric microelectrodes for mercury trace analysis in food products - Fruit juices and beer
    Rievaj, M
    Mesaros, S
    Brunova, A
    Bustin, D
    CHEMICAL PAPERS, 1997, 51 (01) : 11 - 14
  • [23] PULSE VOLTAMMETRIC TECHNIQUES APPLIED TO THE ANODIZATION OF COPPER MICROELECTRODES
    WIKIEL, K
    OSTERYOUNG, J
    ELECTROCHIMICA ACTA, 1993, 38 (15) : 2291 - 2296
  • [24] THE HIGH SENSITIVE POLAROGRAPHIC APPARATUS FOR WORK WITH VOLTAMMETRIC MICROELECTRODES
    VEDRAL, Z
    CHEMICKE LISTY, 1987, 81 (08): : 869 - 873
  • [25] VOLTAMMETRIC MEASUREMENTS WITH MICROELECTRODES IN LOW-CONDUCTIVITY SYSTEMS
    PENA, MJ
    FLEISCHMANN, M
    GARRARD, N
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 220 (01) : 31 - 40
  • [26] Voltammetric Detection of Hydrogen Peroxide at Carbon Fiber Microelectrodes
    Sanford, Audrey L.
    Morton, Stephen W.
    Whitehouse, Kelsey L.
    Oara, Hannah M.
    Lugo-Morales, Leyda Z.
    Roberts, James G.
    Sombers, Leslie A.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5205 - 5210
  • [27] EPOXY-BONDED GRAPHITE MICROELECTRODES FOR VOLTAMMETRIC MEASUREMENTS
    WANG, J
    ANALYTICAL CHEMISTRY, 1981, 53 (14) : 2280 - 2283
  • [28] VOLTAMMETRIC STUDIES BEYOND THE SOLVENT LIMITS WITH MICROELECTRODES.
    Malmsten, Richard A.
    White, Henry S.
    1600, (133):
  • [29] Analysis of parameters relative to weak adsorption from voltammetric data
    Wu, XZ
    Hou, Y
    Zhang, WZ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 407 (1-2): : 45 - 49
  • [30] The coupling of diffusion, migration and chemical equilibrium during the voltammetric reduction of weak polyprotic acids
    Xie, YW
    Osteryoung, JG
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 439 (01): : 163 - 171