Voltammetric analysis of weak acids with microelectrodes

被引:20
|
作者
Canhoto, C [1 ]
Matos, M [1 ]
Rodrigues, A [1 ]
Geraldo, MD [1 ]
Bento, MF [1 ]
机构
[1] Univ Minho, Dept Quim, P-4710057 Braga, Portugal
关键词
weak acids analysis; microelectrodes; voltammetry;
D O I
10.1016/j.jelechem.2004.03.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The role of H+ on the steady-state voltammetric limiting current (I-L) of weak acid (HA) reduction was studied considering results from either lactic acid or acetic acid solutions at constant pH. For solutions with pH > pK(a) or pH congruent to pKa the [H+] effect on the I-L vs c(HA) slope was important even when the H+ current contribution was minor. In contrast, when the pH < pK(a) high H+ current contributions were found; nevertheless the I-L VS c(HA) slope was almost insensitive to pH. A general relationship between I-L and c(HA) was derived considering both the H+ current contribution and the dissociation extent. This equation allows the analytical determination of weak acids, alone or in the presence of strong acids, from experimental I-L and pH. Acid identification can also be performed through the expression presented, following the I-L susceptibility to pH at constant c(HA). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 67
页数:5
相关论文
共 50 条
  • [1] Separation of migrational and chemical components in voltammetric currents of the reduction of weak acids at microelectrodes
    Donten, M
    Jaworski, A
    Stojek, Z
    CHEMIA ANALITYCZNA, 1999, 44 (3B): : 647 - 654
  • [2] The simple voltammetric analysis of acids using highly boron-doped diamond macroelectrodes and microelectrodes
    Mitani, Naoko
    Einaga, Yasuaki
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 626 (1-2) : 156 - 160
  • [3] Assessment of Candida utilis growth by voltammetric reduction of acids using microelectrodes
    Rodrigues, A
    Geraldo, MD
    Bento, MF
    Cássio, F
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 566 (01) : 139 - 145
  • [4] Calibration of an array of voltammetric microelectrodes
    Wehrens, R.
    Van der Linden, W. E.
    Analytica Chimica Acta, 334 (1-2):
  • [5] ELECTROCHEMILUMINESCENCE GENERATED WITH VOLTAMMETRIC MICROELECTRODES
    WIGHTMAN, RM
    COLLINSON, MM
    MANESS, KM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 91 - ANYL
  • [6] Calibration of an array of voltammetric microelectrodes
    Wehrens, R
    vanderLinden, WE
    ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) : 93 - 101
  • [7] Voltammetric microelectrodes for biocorrosion studies
    Xu, K
    Dexter, SC
    Luther, GW
    CORROSION, 1998, 54 (10) : 814 - 823
  • [8] Indirect voltammetric analysis of fluoride ions in toothpaste at IDA microelectrodes
    Rievaj, Miroslav
    Svorc, L'ubomir
    Tomcik, Peter
    Cernanska, Monika
    Bustin, Dusan
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 127 - 131
  • [9] VOLTAMMETRIC REDUCTION OF SIMPLE DIHYDROGEN AND TRIHYDROGEN ACIDS AT PT MICROELECTRODES IN THE ABSENCE OF SUPPORTING ELECTROLYTE
    CISZKOWSKA, M
    STOJEK, Z
    OSTERYOUNG, JG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 84 - ANYL
  • [10] Solid microelectrodes for in situ voltammetric measurements
    Pizeta, I
    Billon, G
    Fischer, JC
    Wartel, M
    ELECTROANALYSIS, 2003, 15 (17) : 1389 - 1396