Stopped-flow kinetic studies of the formation and disintegration of polyion complex micelles in aqueous solution

被引:33
|
作者
Zhang, Jingyan [1 ,2 ]
Chen, Sangui [1 ]
Zhu, Zhiyuan [2 ]
Liu, Shiyong [2 ]
机构
[1] Anhui Jianzhu Univ, Anhui Key Lab Adv Bldg Mat, Sch Mat & Chem Engn, Hefei 230601, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Key Lab Soft Matter Chem, Dept Polymer Sci & Engn, Hefei Natl Lab Phys Sci Microscale, Hefei 230026, Anhui, Peoples R China
关键词
BLOCK-COPOLYMER MICELLES; ABC TRIBLOCK COPOLYMERS; CROSS-LINKED MICELLES; MICELLIZATION KINETICS; DIBLOCK COPOLYMERS; POLYELECTROLYTE COMPLEXES; IONOMER BLENDS; DRUG-DELIVERY; COIL OVERLAP; CORE;
D O I
10.1039/c3cp53608d
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The formation of soluble polyion complexes (PICs) from anionic block copolymers, poly(ethylene oxide)-b-poly(sodium 4-styrene sulfonate) (PEO-b-PSSNa) and cationic block copolymers, poly(ethylene oxide)-b-poly(quaternized 2-(dimethyl amino) ethyl methacrylate) (PEO-b-PQDMA) was investigated by fluorescence spectroscopy, laser light scattering (LLS), and stopped-flow light scattering. Colloidally stabilized dispersions could be obtained upon direct mixing of the aqueous solutions of these two block copolymers, which indicated the formation of core-shell nanostructures with the core consisting of interpolymer electrostatic complexes between PSSNa and PQDMA blocks and the corona of PEO block. Both LLS and fluorescence results revealed that the most compact complex micelles formed at the equal molar ratio of oppositely charged SSNa and QDMA residues. The kinetics of the assembly process was studied via stopped-flow upon direct mixing of the two polymer solutions. The complexation process between PEO-b-PQDMA and PEO-b-PSSNa was fast and could finish within seconds. Moreover, the relaxation process can only be detected at near equal SSNa to QDMA molar ratios. The relaxation curves can be well fitted by a double-exponential function, leading to a fast relaxation process related to the initial quasi-equilibrium complex formation and a slow process related to the pre-complex structure rearrangements to the final equilibrium complexes. Both stages are determined as second-order reactions and processed through a micelle fusion-fission mechanism. Fluorescence kinetic studies revealed that the neutralization of an oppositely charged polyion was too fast to be detected and should be completed within the stopped-flow dead-time. Thermodynamic studies revealed that spontaneous complexation is entropy driven. Upon increasing the ionic strength of the solutions, the complexation processes became slower due to the decrease of entropy driving force. The PIC dissociation process was further studied and considered to consist of two competing processes: a second-order process depending on PIC concentration and a first-order process independent of the PIC concentration.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 50 条
  • [21] KINETIC STUDIES OF AMYLOSE-IODINE-IODIDE REACTION BY STOPPED-FLOW METHOD
    HIROMI, K
    SHIBAOKA, T
    ONO, S
    JOURNAL OF BIOCHEMISTRY, 1970, 68 (02): : 205 - &
  • [22] STOPPED-FLOW KINETIC AND EQUILIBRIUM STUDIES OF FILIPIN-III BINDING TO STEROLS
    BITTMAN, R
    CHEN, WC
    BLAU, L
    BIOCHEMISTRY, 1974, 13 (07) : 1374 - 1379
  • [23] DEUTERIUM KINETIC ISOTOPE EFFECT AND STOPPED-FLOW KINETIC-STUDIES OF THE QUINOPROTEIN METHYLAMINE DEHYDROGENASE
    BROOKS, HB
    JONES, LH
    DAVIDSON, VL
    BIOCHEMISTRY, 1993, 32 (10) : 2725 - 2729
  • [24] STOPPED-FLOW KINETIC STUDY OF COPPER(II) CYANIDE REACTION IN WATER AND IN AQUEOUS METHANOL
    NORD, G
    MATTHES, H
    ACTA CHEMICA SCANDINAVICA SERIES A-PHYSICAL AND INORGANIC CHEMISTRY, 1974, A 28 (01): : 13 - 19
  • [25] A STOPPED-FLOW CONTINUOUS-FLOW METHOD FOR KINETIC DETERMINATIONS
    HSIEH, YS
    CROUCH, SR
    ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 277 - 282
  • [26] Kinetics of formation of vesicles from lecithin/sodium xylenesulfonate micelles from stopped-flow measurements
    Campbell, SE
    Zhang, ZQ
    Friberg, SE
    Patel, R
    LANGMUIR, 1998, 14 (03) : 590 - 594
  • [27] STUDIES ON FLOW-INJECTION STOPPED-FLOW FLUORESCENCE KINETIC METHOD FOR DETERMINATION OF TRACE IRON
    HUANG, HP
    CAI, RX
    ZENG, YE
    GAO, DY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1995, 16 (01): : 47 - 49
  • [28] A kinetic-based stopped-flow DPPH• method
    Lucrezia Angeli
    Ksenia Morozova
    Matteo Scampicchio
    Scientific Reports, 13
  • [29] AUTOMATED STOPPED-FLOW KINETIC ANALYSIS OF SERUM ENZYMES
    LOTT, JA
    TURNER, K
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1973, 59 (06) : 846 - 857
  • [30] KINETIC DETERMINATION OF UREA IN SERUM BY STOPPED-FLOW SPECTROPHOTOMETRY
    ANTON, S
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    ANALYTICA CHIMICA ACTA, 1990, 230 (01) : 145 - 150