Biomechanical Effect of Transforaminal Lumbar Interbody Fusion and Axial Interbody Threaded Rod on Range of Motion and S1 Screw Loading in a Destabilized L5-S1 Spondylolisthesis Model

被引:7
|
作者
Fleischer, Gary D. [1 ]
Hart, David [2 ]
Ferrara, Lisa A. [3 ]
Freeman, Andrew L. [4 ]
Avidano, Eugene E. [5 ]
机构
[1] Southern New Hampshire Med Ctr, Nashua, NH 03060 USA
[2] Cleveland Clin, Cleveland, OH 44106 USA
[3] OrthoKinet Technol, Southport, NC USA
[4] Excelen Ctr Bone & Joint Res, Minneapolis, MN USA
[5] TranS1, Wilmington, NC USA
关键词
lumbar spine biomechanics; spondylolisthesis; S1 screw strain; axial threaded rod; TLIF; spinal deformity instrumentation; range of motion; SPONDYLOLYSIS; GRADE;
D O I
10.1097/BRS.0000000000000077
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A cadaveric lumbosacral spondylolytic spondylolisthesis model was used to evaluate the biomechanical function of 2 different interbody spacers. Objective. To analyze and compare the reduction in pedicle screw strain and spine range of motion (ROM) between transforaminal lumbar interbody fusion (TLIF) and an axial interbody threaded rod (AxialITR) in a destabilized L5-S1 spondylolisthesis model. Summary of Background Data. Symptomatic spondylolytic spondylolisthesis is often treated with posterior instrumented fusion augmented by a variety of different interbody devices. Interbody spacers rely primarily on posterior instrumentation to stabilize the spine during fusion, but there may be advantages to the more rigid support offered by an anterior threaded rod. Methods. Pure-moment fl exibility testing was performed on L3-S1 cadaveric specimens in 4 conditions: (1) Intact, (2) L5-S1 pedicle screws (PS) + L5-S1 disc destabilization (DDS), (3) TLIF at L5-S1 + PS + DDS, and (4) AxialITR at L5-S1 + PS + DDS. Specimens were destabilized by performing a complete denucleation at L5S1 and sectioning two-thirds of the annulus' width from anterior to posterior. The S1 PSs were instrumented with strain gauges to measure screw-bending moments and ROM was quantifi ed with a noncontact camera system. Results. S1 screw strains were highest with PS but were signifi cantly reduced by 73% in fl exion and 31% in extension with TLIF (P = 0.004). AxialITR signifi cantly reduced strain by 78% in fl exion and 81% in extension (P = 0.001). ROM was smallest with AxialITR in each test direction at 1.7 +/- 1.8 in fl exion-extension, 1.6 0.9 in lateral bending and 1.3 0.8 in torsion. Conclusion. This study demonstrated that ROM and S1 screwbending moments were reduced with the use of AxialITR and TLIF. Although the TLIF and AxialITR both reduced strains and motion, the AxialITR provided a signifi cant reduction in extension strain when compared with TLIF.
引用
收藏
页码:E82 / E88
页数:7
相关论文
共 50 条
  • [31] Anatomical Feasibility of Right Oblique Approach for L5-S1 Oblique Lumbar Interbody Fusion
    Song, Se-Jin
    Shin, Myung-Hoon
    Kim, Jong-Tae
    WORLD NEUROSURGERY, 2019, 132 : E403 - E408
  • [32] Risk factors for stand-alone L5-S1 anterior lumbar interbody fusion
    Zhao, Long
    Xie, Tianhang
    Zeng, Jiancheng
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (04) : 546 - 546
  • [33] Single Position Lateral Anterior Lumbar Interbody Fusion at L5/S1
    Stienen, Martin N.
    Yoo, Kelly
    Schonfeld, Ethan
    Shah, Vaihabi
    Abikenari, Matthew
    Pangal, Dhiraj
    Chandra, Venita
    Veeravagu, Anand
    NEUROSURGERY, 2025, 96 (3S) : S17 - S25
  • [34] Positional effects of transforaminal interbody spacer placement at the L5-S1 intervertebral disc space: a biomechanical study
    Tallarico, Richard A.
    Lavelle, William F.
    Bianco, Aaron J.
    Taormina, Jennifer L.
    Ordway, Nathaniel R.
    SPINE JOURNAL, 2014, 14 (12): : 3018 - 3024
  • [35] Laparoscopic discectomy with anterior interbody fusion of L5-S1 - Discussion
    Moviel
    Olsen, D
    Slotman
    Kim
    Vignati
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1996, 10 (12): : 1162 - 1163
  • [36] Instrumented lumbar interbody fusion L4–S1 (TLIF L4–S1)
    Matti Scholz
    Philipp Schleicher
    Frank Kandziora
    European Spine Journal, 2017, 26 : 416 - 417
  • [37] Rectocutaneous fistula and nonunion after TranS1 axial lumbar interbody fusion L5-S1 fixation Case report
    Siegel, Geoffrey
    Patel, Nilesh
    Ramakrishnan, Rakesh
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (02) : 197 - 200
  • [38] High Rectal Injury During Trans-1 Axial Lumbar Interbody Fusion L5-S1 Fixation A Case Report
    Botolin, Sergiu
    Agudelo, Juan
    Dwyer, Anthony
    Patel, Vikas
    Burger, Evalina
    SPINE, 2010, 35 (04) : E144 - E148
  • [39] Supine anterior lumbar interbody fusion versus lateral position oblique lumbar interbody fusion at L5-S1: A comparison of two approaches to the lumbosacral junction
    Xi, Zhuo
    Burch, Shane
    Mummaneni, Praveen, V
    Chang, Chih-Chang
    Ruan, Huibing
    Eichler, Charles
    Chou, Dean
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 82 : 134 - 140
  • [40] Safety and efficacy of stand-alone anterior lumbar interbody fusion in low-grade L5-S1 isthmic spondylolisthesis
    Jesse, C. Marvin
    Schwarzenbach, Othmar
    Ulrich, Christian T.
    Hani, Levin
    Raabe, Andreas
    Schar, Ralph T.
    BRAIN AND SPINE, 2022, 2