共 50 条
Image Processing to Improve Detection of Mesial Temporal Sclerosis in Adults
被引:3
|作者:
Dahi, F.
[1
]
Parsons, M. S.
[2
]
Orlowski, H. L. P.
[2
]
Salter, A.
[3
]
Dahiya, S.
[4
]
Sharma, A.
[2
]
机构:
[1] Progress Phys Assoc, Bethlehem, PA USA
[2] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Campus Box 8131,510 5 Kingshighway Blvd, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Dept Biostat, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO 63110 USA
关键词:
LOBE EPILEPSY;
T2;
RELAXOMETRY;
MRI;
AGREEMENT;
D O I:
10.3174/ajnr.A6022
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
In this retrospective case-control study, we investigated whether an image-processing algorithm designed to exaggerate the intensity of diseased hippocampi on FLAIR images can improve the diagnostic accuracy and interobserver reliability of radiologists in detecting mesial temporal sclerosis-related hippocampal signal alteration. Herein, we share the results of this study that showed that the image processing improved the confidence of radiologists in detecting mesial temporal sclerosis-related signal alteration, allowing an improved sensitivity, specificity, and interobserver reliability.
引用
收藏
页码:798 / 801
页数:4