Cavity ring-down spectroscopy on a high power rf driven source for negative hydrogen ions

被引:59
|
作者
Berger, M. [1 ]
Fantz, U. [1 ]
Christ-Koch, S. [1 ]
机构
[1] Max Planck Inst Plasma Phys, EURATOM Assoc, D-85748 Garching, Germany
来源
PLASMA SOURCES SCIENCE & TECHNOLOGY | 2009年 / 18卷 / 02期
关键词
H IONS; ABSORPTION; PLASMA; EXTRACTION; DENSITIES;
D O I
10.1088/0963-0252/18/2/025004
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Cavity ring-down spectroscopy (CRDS) is a very sensitive diagnostic technique for absorption measurements. It is capable of measuring the absolute line-of-sight (LOS) integrated density of negative hydrogen ions (H-, D-) which induce a weak absorption (a similar or equal to 10(-6) cm(-1)) along a LOS in plasmas containing negative hydrogen ions. CRDS has been applied to a high power rf driven negative ion source which is now the reference source for the ITER neutral beam injection system. The rf source operates at low pressure (typically 0.3 Pa). Negative hydrogen ions are produced mainly by the conversion of hydrogen particles at a caesium coated surface achieving negative ion densities comparable to the electron density near the surface. It is shown that CRDS very reliably measures the absolute volume density of negative hydrogen ions in these sources. The densities range from 10(16) m(-3) in volume operation to 10(17) m(-3) in caesium seeded operation. The measured volume density close to the extraction system and the extracted current density change consistently while varying different source parameters, such as the total pressure or the input power applied to the source. Results are shown for measurements in hydrogen and deuterium discharges with caesium seeding. An additional absorption is measured in the afterglow of the discharge and is attributed to the caesium dimer Cs-2.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER
    Pasqualotto, R.
    Alfier, A.
    Lotto, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [2] Study on Cavity Ring-Down Spectroscopy in High Power Ion Source
    Hu Chun-dong
    Yan Jing-yang
    Wang Yan
    Liang Li-zhen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (02) : 346 - 351
  • [3] Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source
    Nakano, Haruhisa
    Tsumori, Katsuyoshi
    Nagaoka, Kenichi
    Shibuya, Masayuki
    Fantz, Ursel
    Kisaki, Masashi
    Ikeda, Katsunori
    Osakabe, Masaki
    Kaneko, Osamu
    Asano, Eiji
    Kondo, Tomoki
    Sato, Mamoru
    Komada, Seiji
    Sekiguchi, Haruo
    Takeiri, Yasuhiko
    SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390
  • [4] Cavity ring-down spectroscopy
    Zare, RN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 215 : U83 - U83
  • [5] Cavity ring-down spectroscopy
    Wheeler, MD
    Newman, SM
    Orr-Ewing, AJ
    Ashfold, MNR
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1998, 94 (03): : 337 - 351
  • [6] Cavity ring-down spectroscopy sensor for detection of hydrogen chloride
    Hagen, C. L.
    Lee, B. C.
    Franka, I. S.
    Rath, J. L.
    VandenBoer, T. C.
    Roberts, J. M.
    Brown, S. S.
    Yalin, A. P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (02) : 345 - 357
  • [7] Differential cavity ring-down spectroscopy
    Courtois, Jeromie
    Bielska, Katarzyna
    Hodges, Joseph T.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2013, 30 (06) : 1486 - 1495
  • [8] Fast and Accurate Extraction of Ring-Down Time in Cavity Ring-Down Spectroscopy
    Wang Dan
    Hu Ren-zhi
    Xie Pin-hua
    Qin Min
    Ling Liu-yi
    Duan Jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (10) : 2845 - 2850
  • [9] High sensitivity detectors based on cavity ring-down spectroscopy
    Paldus, BA
    Fidric, BG
    Sanders, SS
    Tan, SM
    Pham, H
    Kachanov, AA
    Wahl, EH
    Crosson, ER
    OPTICALLY BASED BIOLOGICAL AND CHEMICAL SENSING FOR DEFENCE, 2004, 5617 : 312 - 322
  • [10] Investigation of hydrogen sulfide adsorption using cavity ring-down spectroscopy
    Xiong, Feng
    Peng, Zhimin
    Ding, Yanjun
    Lyu, Junfu
    Du, Yanjun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (04)