Comparative Analysis of Existing RC Columns Jacketed with CFRP or FRCC

被引:37
|
作者
Del Zoppo, Marta [1 ]
Di Ludovico, Marco [2 ]
Balsamo, Alberto [2 ]
Prota, Andrea [2 ]
机构
[1] Univ Naples Parthenope, Dept Engn, I-80143 Naples, Italy
[2] Univ Naples Federico II, Dept Struct Engn & Architecture, I-80125 Naples, Italy
关键词
existing RC columns; CFRP; FRCC; repair; strengthening; seismic retrofit; REINFORCED-CONCRETE COLUMNS; SHEAR-STRENGTH; SEISMIC RETROFIT; DAMAGE MODEL; PERFORMANCE; FRP; MEMBERS;
D O I
10.3390/polym10040361
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Reinforced concrete (RC) columns typical of existing structures often exhibit premature failures during seismic events (i.e., longitudinal bars buckling and shear interaction mechanisms) due to the poor quality concrete and the absence of proper seismic details in the potential plastic hinge region. The Fiber Reinforced Polymers (FRP) externally bonded reinforcement is known to be a valid technique to improve the shear capacity or the ductility of existing RC columns. However, few experimental tests have proven its effectiveness in the case of columns affected by shear interaction mechanisms. In this work, the behavior of existing RC columns with border line behavior between flexure and shear have been investigated in the case of poor quality concrete and light FRP strengthening with local jacketing and medium quality concrete and strong FRP strengthening with local jacketing, in order to highlight the effect of concrete strength on the effectiveness of the retrofit intervention. As an alternative to FRP jacketing; the effectiveness of the Fiber Reinforced Cementitious Composite (FRCC) jacketing for the seismic strengthening of columns with highly deteriorated concrete cover or columns already damaged by an earthquake is also evaluated. Six full-scale RC columns have been tested under cyclic loading: one was used as a control specimen; four were strengthened in the potential plastic hinge region with carbon FRP (CFRP); and one was fully jacketed with FRCC. The comparison between poor and medium quality concrete columns showed that the CFRP local jacketing is more effective in the case of poor quality concrete. The FRCC jacketing appears to be a sound repair strategy and a suitable alternative to the FRP jacketing in case of poor quality; however, more experimental research is needed for improving this retrofit technique.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Repair, flexural upgrading and seismic retrofit of RC columns with reinforced FRCC light jacket
    Del Zoppo, Marta
    Di Ludovico, Marco
    Balsamo, Alberto
    Prota, Andrea
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 408
  • [22] Seismic behaviour of RC jacketed columns under different axial loads
    Yang, Keun-Hyeok
    Hwang, Seung-Hyeon
    Mun, Ju-Hyun
    MAGAZINE OF CONCRETE RESEARCH, 2021, 73 (17) : 879 - 889
  • [23] ANALYTICAL MODEL FOR STEEL-JACKETED RC CIRCULAR BRIDGE COLUMNS
    CHAI, YH
    PRIESTLEY, MJN
    SEIBLE, F
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (08): : 2358 - 2376
  • [24] Modified Steel-Jacketed Columns for Combined Blast and Seismic Retrofit of Existing Bridge Columns
    Fouche, Pierre
    Bruneau, Michel
    Chiarito, Vincent P.
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (07)
  • [25] Analysis of load-strain models for RC square columns confined with CFRP
    Faustino, Pedro
    Chastre, Carlos
    COMPOSITES PART B-ENGINEERING, 2015, 74 : 23 - 41
  • [26] Experimental performance of RC hollow columns confined with CFRP
    Lignola, G. P.
    Prota, A.
    Manfredi, G.
    Cosenza, E.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (01) : 42 - 49
  • [27] Blast testing of CFRP and SRP strengthened RC columns
    Berger, J. -O.
    Heffernan, P. J.
    Wight, R. G.
    STRUCTURES UNDER SHOCK AND IMPACT X, 2008, 98 : 95 - 104
  • [28] Retrofit of Damaged RC Columns Using CFRP Jackets
    Moretti, Marina L.
    Miliokas, Evangelos
    Paparizos, Ioannis
    Lecture Notes in Civil Engineering, 2022, 198 LNCE : 1229 - 1240
  • [29] Seismic performance of RC columns retrofitted with CFRP strips
    Araki, H.
    Sato, R.
    Kabayama, K.
    Nakata, M.
    FRACTURE MECHANICS OF CONCRETE AND CONCRETE STRUCTURES, VOLS 1-3: VOL 1: NEW TRENDS IN FRACTURE MECHANICS OF CONCRETE; VOL 2: DESIGN, ASSESSMENT AND RETROFITTING OF RC STRUCTURES; VOL 3: HIGH-PERFORMANCE CONCRETE, BRICK-MASONRY AND ENVIRONMENTAL ASPECTS, 2007, 1-3 : 1121 - +
  • [30] Utilization of CFRP for strengthening RC columns in marine environment
    Alsaad, Alaa
    Hassan, Gulan
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2017, 7 : 30 - 35