Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience

被引:50
|
作者
Lv, Peijie [1 ]
Liu, Jie [1 ]
Chai, Yaru [1 ]
Yan, Xiaopeng [1 ]
Gao, Jianbo [1 ]
Dong, Junqiang [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, 1 East Jianshe Rd, Zhengzhou 450052, Henan Province, Peoples R China
关键词
Dual-energy CT; Spectral CT; Monochromatic image; Iterative reconstruction; Contrast agent; LOW-TUBE-VOLTAGE; MULTIDETECTOR-ROW CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; INDUCED NEPHROPATHY; RADIATION-EXPOSURE; INJECTION DURATION; RENAL-FAILURE; DYNAMIC CT; 80; KVP;
D O I
10.1007/s00330-016-4349-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. aEuro cent Automatic spectral imaging protocol selection provides appropriate scan protocols. aEuro cent Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. aEuro cent 50-keV monochromatic images with 50 % ASIR provide optimal image quality.
引用
收藏
页码:374 / 383
页数:10
相关论文
共 50 条
  • [41] Lowering Kilovoltage to Reduce Radiation Dose in Contrast-Enhanced Abdominal CT: Initial Assessment of a Prototype Automated Kilovoltage Selection Tool
    Hough, David M.
    Fletcher, Joel G.
    Grant, Katharine L.
    Fidler, Jeff L.
    Yu, Lifeng
    Geske, Jennifer R.
    Carter, Rickey E.
    Raupach, Rainer
    Schmidt, Bernhard
    Flohr, Thomas
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 1070 - 1077
  • [42] Low Contrast Agent and Radiation Dose Protocol for Hepatic Dynamic CT of Thin Adults at 256-Detector Row CT: Effect of Low Tube Voltage and Hybrid Iterative Reconstruction Algorithm on Image Quality
    Nakaura, Takeshi
    Nakamura, Shinichi
    Maruyama, Natsuki
    Funama, Yoshinori
    Awai, Kazuo
    Harada, Kazunori
    Uemura, Shouzaburou
    Yamashita, Yasuyuki
    RADIOLOGY, 2012, 264 (02) : 445 - 454
  • [43] Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging
    Si-Mohamed, Salim
    Thivolet, Arnaud
    Bonnot, Pierre-Emmanuel
    Bar-Ness, Daniel
    Kepenekian, Vahan
    Cormode, David P.
    Douek, Philippe
    Rousset, Pascal
    INVESTIGATIVE RADIOLOGY, 2018, 53 (10) : 629 - 639
  • [44] Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance
    McLaughlin P.D.
    Murphy K.P.
    Hayes S.A.
    Carey K.
    Sammon J.
    Crush L.
    O'Neill F.
    Normoyle B.
    McGarrigle A.M.
    Barry J.E.
    Maher M.M.
    Insights into Imaging, 2014, 5 (2) : 217 - 230
  • [45] Hybrid Iterative Reconstruction Technique for Abdominal CT Protocols in Obese Patients: Assessment of Image Quality, Radiation Dose, and Low-Contrast Detectability in a Phantom
    Schindera, Sebastian T.
    Odedra, Devang
    Mercer, Diego
    Thipphavong, Seng
    Chou, Paul
    Szucs-Farkas, Zsolt
    Rogalla, Patrik
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : W146 - W152
  • [46] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Zhao, Lei
    Liu, Aishi
    Guo, Youmin
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 724 - 732
  • [47] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Lei Zhao
    Aishi Liu
    Youmin Guo
    Japanese Journal of Radiology, 2017, 35 : 724 - 732
  • [48] A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
    Machida, Haruhiko
    Fukui, Rika
    Tanaka, Isao
    Shen, Yun
    Ishikawa, Takuya
    Tate, Etsuko
    Suzuki, Shigeru
    Ueno, Eiko
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (04) : 217 - 223
  • [49] A method for selecting a protocol for routine body CT scan using Gemstone Spectral Imaging with or without adaptive statistical iterative reconstruction: phantom experiments
    Haruhiko Machida
    Rika Fukui
    Isao Tanaka
    Yun Shen
    Takuya Ishikawa
    Etsuko Tate
    Shigeru Suzuki
    Eiko Ueno
    Japanese Journal of Radiology, 2014, 32 : 217 - 223
  • [50] CT evaluation of living liver donor: Can 100-kVp plus iterative reconstruction protocol provide accurate liver volume and vascular anatomy for liver transplantation with reduced radiation and contrast dose?
    Yoshida, Morikatsu
    Utsunomiya, Daisuke
    Kidoh, Masafumi
    Yuki, Hideaki
    Oda, Seitaro
    Shiraishi, Shinya
    Yamamoto, Hidekazu
    Inomata, Yukihiro
    Yamashita, Yasuyuki
    MEDICINE, 2017, 96 (23)