Biomechanical analysis of the rigid fixation of zygoma fractures: An experimental study

被引:28
|
作者
Deveci, M [1 ]
Eski, M
Gurses, S
Yucesoy, CA
Selmanpakoglu, N
Akkas, N
机构
[1] Gulhane Mil Med Acad, Dept Plast Reconstruct Surg, TR-06018 Ankara, Turkey
[2] Middle E Tech Univ, Lab Biomech, Ankara, Turkey
关键词
zygoma fracture; rigid fixation; biomechanical analysis;
D O I
10.1097/00001665-200407000-00013
中图分类号
R61 [外科手术学];
学科分类号
摘要
In this experimental study, the goal was to test the sufficiency of actual fixation plates in zygomatic complex fractures and the efficiency of a modified plate at the zygomaticofrontal suture in a suitable model, which was designed for biomechanical study. To address this issue, a zygomatic fracture model produced by using a cadaveric cranium was simulated and the fractures were fixed by the actual and modified fixation materials. The force simulating masseter muscle pull was applied with the Lloyd material testing apparatus, and the rotation of the zygoma was determined using displacement transducers. In this study, there were three different experimental groups. Although miniplates at the zygomaticomaxillary buttress and microplates at the infraorbital rim were used in all three groups, three different plates (miniplate, microplate, and modified plate) were used at the frontozygomatic suture in these groups. Rotational displacement of the zygoma with the effects of simulated masseter muscle force was determined. According to the results obtained, microplates are not effective in stabilizing the frontozygomatic suture when the masseter muscle forces are within physiological range. Although miniplates stabilize zygomatic complex fractures, it was shown that modified microplates, which have no ondulation along the plate border, have a higher resistance to rotation than that of the conventional plates. The rotation angle at the instant of fracture with microplates was 4.59, and that with miniplates was 1.26. The maximum rotation angle with modified microplates was 0.32. Modified microplates designed for the fixation of fractures in the zygomatico-orbital region have been shown to be suitable in a well-designed experimental model and might be appropriate for clinical use.
引用
收藏
页码:595 / 602
页数:8
相关论文
共 50 条
  • [21] Intramedullary screw fixation of Jones fractures: A biomechanical study
    Pietropaoli, MP
    Wnorowski, DC
    Werner, FW
    Fortino, MD
    FOOT & ANKLE INTERNATIONAL, 1999, 20 (09) : 560 - 563
  • [22] Evaluation of Fixation Techniques With Titanium Plates and Kirschner Wires for Zygoma Fractures: Preliminary Study
    Chaves Moreno, Eduardo Fernando
    do Egito Vasconcelos, Belmiro Cavalcanti
    de Aguiar Soares Carneiro, Suzana Celia
    Catunda, Ivson Souza
    Melo, Auremir Rocha
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (10) : 2386 - 2393
  • [23] 3-POINT ALIGNMENT OF ZYGOMA FRACTURES WITH MINIPLATE FIXATION
    HOLMES, KD
    MATTHEWS, BL
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1989, 115 (08) : 961 - 963
  • [24] Transcutaneous reduction and external fixation for the treatment of noncomminuted zygoma fractures
    Kim, YO
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (12) : 1382 - 1387
  • [25] COMPARISON OF RIGID PLATE VERSUS WIRE FIXATION IN THE MANAGEMENT OF ZYGOMA FRACTURES - A LONG-TERM FOLLOW-UP CLINICAL-STUDY
    ROHRICH, RJ
    WATUMULL, D
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 96 (03) : 570 - 575
  • [26] Biomechanical comparison of three fixation strategies for radial head fractures: a biomechanical study
    Tsai, Yao-Tung
    Lin, Kun-Jhih
    Lin, Jui-Cheng
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (02): : 193 - 198
  • [27] RIGID FIXATION OF FRACTURES BY COMPRESSION PLATING - A PILOT STUDY
    HESKETH, KT
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1968, 61 (10): : 983 - &
  • [28] RIGID SKELETAL FIXATION OF FRACTURES
    ELLIS, E
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (02) : 163 - 173
  • [29] Internal fixation of radial neck fractures: an in vitro biomechanical analysis
    Giffin, JR
    King, GJW
    Patterson, SD
    Johnson, JA
    CLINICAL BIOMECHANICS, 2004, 19 (04) : 358 - 361
  • [30] Displaced olecranon fractures in children - A biomechanical analysis of fixation methods
    Parent, Stefan
    Kedemeyer, Michelle
    Mahar, Andrew T.
    Anderson, Megan
    Taro, Frances
    Steinman, Suzanne
    Lalonde, Franqois
    Newton, Peter
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2008, 28 (02) : 147 - 151