Biomechanical analysis of the rigid fixation of zygoma fractures: An experimental study

被引:28
|
作者
Deveci, M [1 ]
Eski, M
Gurses, S
Yucesoy, CA
Selmanpakoglu, N
Akkas, N
机构
[1] Gulhane Mil Med Acad, Dept Plast Reconstruct Surg, TR-06018 Ankara, Turkey
[2] Middle E Tech Univ, Lab Biomech, Ankara, Turkey
关键词
zygoma fracture; rigid fixation; biomechanical analysis;
D O I
10.1097/00001665-200407000-00013
中图分类号
R61 [外科手术学];
学科分类号
摘要
In this experimental study, the goal was to test the sufficiency of actual fixation plates in zygomatic complex fractures and the efficiency of a modified plate at the zygomaticofrontal suture in a suitable model, which was designed for biomechanical study. To address this issue, a zygomatic fracture model produced by using a cadaveric cranium was simulated and the fractures were fixed by the actual and modified fixation materials. The force simulating masseter muscle pull was applied with the Lloyd material testing apparatus, and the rotation of the zygoma was determined using displacement transducers. In this study, there were three different experimental groups. Although miniplates at the zygomaticomaxillary buttress and microplates at the infraorbital rim were used in all three groups, three different plates (miniplate, microplate, and modified plate) were used at the frontozygomatic suture in these groups. Rotational displacement of the zygoma with the effects of simulated masseter muscle force was determined. According to the results obtained, microplates are not effective in stabilizing the frontozygomatic suture when the masseter muscle forces are within physiological range. Although miniplates stabilize zygomatic complex fractures, it was shown that modified microplates, which have no ondulation along the plate border, have a higher resistance to rotation than that of the conventional plates. The rotation angle at the instant of fracture with microplates was 4.59, and that with miniplates was 1.26. The maximum rotation angle with modified microplates was 0.32. Modified microplates designed for the fixation of fractures in the zygomatico-orbital region have been shown to be suitable in a well-designed experimental model and might be appropriate for clinical use.
引用
收藏
页码:595 / 602
页数:8
相关论文
共 50 条
  • [1] A comparative biomechanical analysis of resorbable rigid fixation versus titanium rigid fixation of metacarpal fractures
    Prevel, CD
    Eppley, BL
    Ge, J
    Winkler, MM
    Katona, TR
    DAlessio, K
    Sarver, D
    ANNALS OF PLASTIC SURGERY, 1996, 37 (04) : 377 - 385
  • [2] FRACTURES OF THE ZYGOMA - GEOMETRIC, BIOMECHANICAL, AND SURGICAL ANALYSIS
    KARLAN, MS
    CASSISI, NJ
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1979, 105 (06) : 320 - 327
  • [3] THE HEALING OF EXPERIMENTAL FRACTURES AFTER RIGID PLATE FIXATION, INTRA-MEDULLARY NAILING AND EXTERNAL FIXATION - A BIOMECHANICAL STUDY IN RABBITS
    HOLMSTROM, T
    PAAVOLAINEN, P
    SLATIS, P
    KAARTINEN, E
    AALTO, K
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 706 - 706
  • [4] Rigid internal fixation of zygoma fractures: A comparison of two-point and three-point fixation
    Parashar, Atul
    Sharma, Ramesh K.
    Makkar, Surinder
    INDIAN JOURNAL OF PLASTIC SURGERY, 2007, 40 (01) : 18 - 24
  • [5] Internal fixation of experimental intraarticular calcaneal fractures: A biomechanical analysis of two fixation methods
    Carr, JB
    Tigges, RG
    Wayne, JS
    Earll, M
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) : 425 - 428
  • [6] Rigid fixation of the sternum: a comparative biomechanical study
    Orhan, Sueleyman Nazif
    Alkan, Eda
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (06)
  • [7] Biomechanical Optimization of Bone Plates Used in Rigid Fixation of Mandibular Fractures
    Lovald, Scott T.
    Wagner, Jon D.
    Baack, Bret
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (05) : 973 - 985
  • [8] A BIOMECHANICAL STUDY OF ODONTOID FRACTURES AND FRACTURE FIXATION
    DOHERTY, BJ
    HEGGENESS, MH
    ESSES, SI
    SPINE, 1993, 18 (02) : 178 - 184
  • [9] Fixation of segmental subtrochanteric fractures - A biomechanical study
    Kraemer, WJ
    Hearn, TC
    Powell, JN
    Mahomed, N
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (332) : 71 - 79
  • [10] Rigid plate versus wire fixation for zygoma fracture
    Top, H
    Atabey, A
    Barutcu, A
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (06) : 1117 - 1118