The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging

被引:9
|
作者
Bazalova-Carter, Magdalena [1 ,2 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1055期
关键词
COMPUTED-TOMOGRAPHY XFCT; NANOPARTICLE-LOADED OBJECTS; GOLD NANOPARTICLES; CANCER; AGENT;
D O I
10.1259/bjr.20140308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
X-ray fluorescence CT (XFCT), a novel modality proposed for high-sensitivity high-resolution molecular imaging of probes labelled with a high atomic-number element, has been performed with high-energy K-shell X-rays. XFCT performed with low-energy L-shell X-rays could, in principle, result in an increase of XFCT imaging sensitivity; however, the significant L-shell X-ray attenuation limits its use for imaging of small objects. This commentary discusses the advantages and drawbacks of L-shell XFCT imaging.
引用
收藏
页数:3
相关论文
共 50 条
  • [11] Experimental validation of L-shell x-ray fluorescence computed tomography imaging: phantom study
    Bazalova-Carter, Magdalena
    Ahmad, Moiz
    Xing, Lei
    Fahrig, Rebecca
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [12] ON THE VIABILITY OF EXPLOITING L-SHELL FLUORESCENCE FOR X-RAY POLARIMETRY.
    Weisskopf, M.C.
    Sutherland, P.G.
    Elsner, R.F.
    Ramsey, B.D.
    Nuclear instruments and methods in physics research, 1985, A236 (02): : 371 - 374
  • [14] Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source
    Manohar, Nivedh
    Reynoso, Francisco J.
    Cho, Sang Hyun
    MEDICAL PHYSICS, 2013, 40 (08)
  • [15] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [16] Localization and Quantification of Gold Nanoparticles Using L-Shell Fluorescence Imaging with a Benchtop X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [17] L-shell X-ray fluorescence measurements of lead in bone: accuracy and precision
    Todd, AC
    Carroll, S
    Geraghty, C
    Khan, FA
    Moshier, EL
    Tang, S
    Parsons, PJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08): : 1399 - 1419
  • [18] L-shell x-ray fluorescence measurements of lead in bone: theoretical considerations
    Todd, AC
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03): : 491 - 505
  • [19] Feasibility of Direct L-Shell Fluorescence Imaging of Gold Nanoparticles Using a Benchtop X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3987 - 3988
  • [20] L-shell x-ray fluorescence measurements of lead in bone: system development
    Todd, AC