Compressed-sensing (CS)-based digital breast tomosynthesis (DBT) reconstruction for low-dose, accurate 3D breast X-ray imaging

被引:3
|
作者
Park, Yeonok [1 ,2 ]
Cho, Hyosung [1 ,2 ]
Je, Uikyu [1 ,2 ]
Hong, Daeki [1 ,2 ]
Lee, Minsik [1 ,2 ]
Park, Chulkyu [1 ,2 ]
Cho, Heemoon [1 ,2 ]
Choi, Sungil [1 ,2 ]
Koo, Yangseo [1 ,2 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
[2] Yonsei Univ, VYS Res Ctr, Wonju 220710, South Korea
关键词
Digital breast tomosynthesis; Filtered backprojection (FBP); Compressed-sensing (CS); BEAM COMPUTED-TOMOGRAPHY;
D O I
10.3938/jkps.65.565
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In practical applications of three-dimensional (3D) tomographic techniques, such as digital breast tomosynthesis (DBT), computed tomography (CT), etc., there are often challenges for accurate image reconstruction from incomplete data. In DBT, in particular, the limited-angle and few-view projection data are theoretically insufficient for exact reconstruction; thus, the use of common filtered-backprojection (FBP) algorithms leads to severe image artifacts, such as the loss of the average image value and edge sharpening. One possible approach to alleviate these artifacts may employ iterative statistical methods because they potentially yield reconstructed images that are in better accordance with the measured projection data. In this work, as another promising approach, we investigated potential applications to low-dose, accurate DBT imaging with a state-of-the-art reconstruction scheme based on compressed-sensing (CS) theory. We implemented an efficient CS-based DBT algorithm and performed systematic simulation works to investigate the imaging characteristics. We successfully obtained DBT images of substantially very high accuracy by using the algorithm and expect it to be applicable to developing the next-generation 3D breast X-ray imaging system.
引用
收藏
页码:565 / 571
页数:7
相关论文
共 50 条
  • [31] Optimal angular dose distribution to acquire 3D and extra 2D images for digital breast tomosynthesis (DBT)
    Hye-Suk Park
    Ye-Seul Kim
    Haeng-Hwa Lee
    Won-Suk Gang
    Hee-Joung Kim
    Young-Wook Choi
    JaeGu Choi
    Journal of the Korean Physical Society, 2015, 67 : 590 - 598
  • [32] Fabrication of 3D printed patient-derived anthropomorphic breast phantoms for mammography and digital breast tomosynthesis: Imaging assessment with clinical X-ray spectra
    Varallo, Antonio
    Sarno, Antonio
    Castriconi, Roberta
    Mazzilli, Aldo
    Loria, Alessandro
    del Vecchio, Antonella
    Orientale, Antonio
    Pilotti, Immacolata A. M.
    D'Andria, Pasquale
    Bliznakova, Kristina
    Ricciardi, Roberta
    Mettivier, Giovanni
    Russo, Paolo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 98 : 88 - 97
  • [33] Comparison of high-resolution 3D X-ray microCT and tomosynthesis imaging: A breast phantom study
    Singh, Jolene M.
    Bui, Anthony H.
    Michaelson, James S.
    CANCER RESEARCH, 2014, 74 (19)
  • [34] Development of a chest digital tomosynthesis R/F system and implementation of low-dose GPU-accelerated compressed sensing (CS) image reconstruction
    Choi, Sunghoon
    Lee, Haenghwa
    Lee, Donghoon
    Choi, Seungyeon
    Lee, Chang-Lae
    Kwon, Woocheol
    Shin, Jungwook
    Seo, Chang-Woo
    Kim, Hee-Joung
    MEDICAL PHYSICS, 2018, 45 (05) : 1871 - 1888
  • [35] 3D Microwave Nearfield Radar Imaging (NRI) Using Digital Breast Tomosynthesis (DBT) for Non-Invasive Breast Cancer Detection
    Obermeier, Richard
    Tivnan, Matthew
    Rappaport, Carey M.
    Martinez-Lorenzo, Jose A.
    2014 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2014, : 258 - 258
  • [36] Characterization of X-ray scatter and glandular dose in digital tomosynthesis for breast imaging using Monte Carlo simulations
    Sechopoulos, I.
    Suryanarayanan, S.
    Vedantham, S.
    Karellas, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 1990 - 1990
  • [37] Cone beam x-ray CT will be superior to digital x-ray tomosynthesis in imaging the breast and delineating cancer
    Karellas, Andrew
    Lo, Joseph Y.
    Orton, Colin G.
    MEDICAL PHYSICS, 2008, 35 (02) : 409 - 411
  • [38] 3D Model-based Reconstruction of the Proximal Femur from Low-dose Biplanar X-Ray Images
    Boussaid, Haithem
    Kadoury, Samuel
    Kokkinos, Iasonas
    Lazennec, Jean-Yves
    Zheng, Guoyan
    Paragios, Nikos
    PROCEEDINGS OF THE BRITISH MACHINE VISION CONFERENCE 2011, 2011,
  • [39] Digital simulation for 3D reconstruction of coherent x-ray diffractive imaging
    Zhou Guang-Zhao
    Wang Yu-Dan
    Ren Yu-Qi
    Chen Can
    Ye Lin-Lin
    Xiao Ti-Qiao
    ACTA PHYSICA SINICA, 2012, 61 (01)
  • [40] High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
    Zhao, Yunzhe
    Brun, Emmanuel
    Coan, Paola
    Huang, Zhifeng
    Sztrokay, Aniko
    Diemoz, Paul Claude
    Liebhardt, Susanne
    Mittone, Alberto
    Gasilov, Sergei
    Miao, Jianwei
    Bravin, Alberto
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (45) : 18290 - 18294