A NOVEL METHOD TO MEASURE THE SAGITTAL CURVATURE IN SPINAL DEFORMITIES: THE RELIABILITY AND FEASIBILITY OF 3-D ULTRASOUND IMAGING

被引:18
|
作者
Lee, Timothy Tin-Yan [1 ]
Jiang, Wei Wei [2 ]
Cheng, Connie Lok Kan [1 ]
Lai, Kelly Ka-Lee [1 ]
To, Michael Kai Tsun [3 ]
Castelein, Rene M. [4 ]
Cheung, Jason Pui Yin [3 ]
Zheng, Yong-Ping [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Biomed Engn, Hong Kong, Peoples R China
[2] Zhejiang Univ Technol, Coll Comp Sci & Technol, Hangzhou, Zhejiang, Peoples R China
[3] Univ Hong Kong, Dept Orthopaed & Traumatol, Hong Kong, Peoples R China
[4] Univ Med Ctr Utrecht, Dept Orthopaed Surg, Utrecht, Netherlands
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2019年 / 45卷 / 10期
关键词
3-D ultrasound; Scoliosis; Sagittal; Spinous processes; ADOLESCENT IDIOPATHIC SCOLIOSIS; CANCER-MORTALITY; 3D ULTRASOUND; LUMBAR SPINE; COBB ANGLE; SYSTEM; ALIGNMENT; ACCURACY; RADIOGRAPHS; SURGERY;
D O I
10.1016/j.ultrasmedbio.2019.05.031
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this study was to test the reliability of sagittal spinal curvature measurements using 3-D ultrasound in patients with adolescent idiopathic scoliosis (AIS). Ultrasound spinous process angle (USSPA) and ultrasound laminae angle (USLA) were measured on sagittal ultrasound images, while the Cobb angle (XCA) was measured on sagittal X-ray images. Intra-class correlation coefficients (ICC) for the intra- and inter-observer variability, linear regression analysis and Bland-Altman method, including mean absolute difference (MAD), were investigated to evaluate the reliability and validity of the two ultrasound angles compared with XCA. Excellent measurement reliabilities were demonstrated for both ultrasound angles (ICC >= 0.91). Moderate to good and significant linear correlations and good agreement were demonstrated between the ultrasound methods and XCA (Thoracic [R-2 >= 0.574] / Lumbar [R-2 >= 0.635]). No significant differences were found for the MADs between both corrected ultrasound angles and XCA. Sagittal ultrasound angles were demonstrated to be reliable for assessing sagittal curvature using spinous processes and laminae and to have good and significant correlations with XCAs. Since it is non-ionizing and relatively low cost, this method opens the possibility of providing frequent curve monitoring and evaluation, and screening for MS patients, particularly based on sagittal profiles. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2725 / 2735
页数:11
相关论文
共 50 条
  • [31] CLINICAL FEASIBILITY OF 3-D FRACTIONAL TREATMENTS WITH FOCUSED ULTRASOUND
    Anderson, R. Rox
    Slayton, Michael
    Miller, Randall
    Call, Aaron
    LASERS IN SURGERY AND MEDICINE, 2010, : 31 - 32
  • [32] Inter-Evaluator Reliability of Sagittal and Rotational Spinal Measurements from 3D Ultrasound Imaging of Healthy Females in Standing with Varying Arm Positions
    Ganci, Aislinn
    Qazizada, Miran
    Fehr, Brianna
    Vucenovic, Ana
    Lou, Edmond
    Parent, Eric
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2024, 28 (04) : 338 - 347
  • [33] Reliability of 3-D ultrasound of cervical lymph node volume
    Ying, Michael
    Pang, Shuk-Fan
    Sin, Man-Hong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (07): : 995 - 1001
  • [34] ULTRASOUND IMAGING IN 3-D - IMAGE-PROCESSING
    HIGGINS, M
    COMPUTER GRAPHICS WORLD, 1983, 6 (03) : 89 - 89
  • [35] Reliability and validity of splenic volume measurement by 3-D ultrasound
    Hidaka, Hisashi
    Nakazawa, Takahide
    Wang, Guoqin
    Kokubu, Shigehiro
    Minamino, Tsutomu
    Takada, Juichi
    Tanaka, Yoshiaki
    Okuwaki, Yusuke
    Watanabe, Masaaki
    Shibuya, Akitaka
    Koizumi, Wasaburo
    HEPATOLOGY RESEARCH, 2010, 40 (10) : 979 - 988
  • [36] 3-D imaging of residual limbs using ultrasound
    He, P
    Xue, KF
    Murka, P
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1997, 34 (03): : 269 - 278
  • [37] Separable Beamforming For 3-D Medical Ultrasound Imaging
    Yang, Ming
    Sampson, Richard
    Wei, Siyuan
    Wenisch, Thomas F.
    Chakrabarti, Chaitali
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2015, 63 (02) : 279 - 290
  • [38] Linear Tracking for 3-D Medical Ultrasound Imaging
    Huang, Qing-Hua
    Yang, Zhao
    Hu, Wei
    Jin, Lian-Wen
    Wei, Gang
    Li, Xuelong
    IEEE TRANSACTIONS ON CYBERNETICS, 2013, 43 (06) : 1747 - 1754
  • [39] FREEHAND 3-D ULTRASOUND IMAGING: A SYSTEMATIC REVIEW
    Mozaffari, Mohammad Hamed
    Lee, Won-Sook
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2099 - 2124
  • [40] Two dimensional Arrays for 3-D ultrasound Imaging
    Smith, SW
    Lee, W
    Light, ED
    Yen, JT
    Wolf, P
    Idriss, S
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1545 - 1553