Protection of equipment engulfed in a pool fire

被引:13
|
作者
PlanasCuchi, E [1 ]
Casal, J [1 ]
Lancia, A [1 ]
Bordignon, L [1 ]
机构
[1] TECSA RIC & INNOVAZZ,SCANZOROSCIATE,BG,ITALY
关键词
pool fire; foam and water; cooling; extinguishing; modelling;
D O I
10.1016/0950-4230(96)00014-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
When process equipment is engulfed in a fire, the protection system should extinguish the fire and simultaneously cool the equipment. Therefore, the behaviour of equipment engulfed in a fire, as well as its eventual influence on the fire, should be known. In this article, experimental data from pool fires of hexane (4 m(2)) and kerosene (12 m(2)) are discussed. The evolution of the fire up to its full engulfment is studied, as is the evolution of temperatures at different points of a tank engulfed in it. The heat release rates under the different operating conditions are studied. A method is developed to calculate the maximum combustion rate, both for the developing stage and for the fully developed fire. The hindering effect of the tank on the fire is discussed and quantified in terms of 'efficiency of hindered combustion'. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:231 / 240
页数:10
相关论文
共 50 条
  • [41] Large scale pool fire with a fully engulfed tank- Experimental data and numerical validation of the flame height and flame behaviour around the tank
    Drean, Virginie
    Girardin, Bertrand
    Guillaume, Bruno
    Chiva, Roman
    Colombiano, Jeremy
    Rengel, Borja
    Desmurger, Thierry
    Mitanchez, Gaetan
    Guillaume, Eric
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2024, 91
  • [42] Fire Protection Measures on Electrical Equipment with Askarel Insulating Liquids.
    Stein, R.
    VGB-Kraftwerkstechnik, 1985, 65 (05): : 507 - 513
  • [43] Fire Protection measures for Electrical Equipment with Liquid Askarel Insulation.
    Stein, Richard
    Der Maschinenschaden Berlin, 1985, 58 (03): : 101 - 109
  • [44] ECONOMIC ANALYSIS OF SURFACE MINING MOBILE EQUIPMENT FIRE PROTECTION SYSTEMS.
    POMROY, WILLIAM H.
    GOODWIN, NEIL
    LYNCH, FRANK
    1982,
  • [45] Analysis and Testing of Fibrous Passive Fire Protection Material for Fireproofing of Equipment Units
    Moricone, Raffaela
    Tugnoli, Alessandro
    Villa, Valeria
    Cozzani, Valerio
    CISAP6: 6TH INTERNATIONAL CONFERENCE ON SAFETY & ENVIRONMENT IN PROCESS & POWER INDUSTRY, 2014, 36 : 331 - 336
  • [46] Modeling flame temperature profile on a fire-engulfed cylindrical tube
    Najafi, Arash
    Moghaddam, Abdolsamad Zarringhalam
    FIRE AND MATERIALS, 2012, 36 (07) : 565 - 574
  • [47] On the fire intensification of pool fire with water mist
    Liang, Tianshui
    Zhong, Wei
    Yuen, Richard K. K.
    Lo, Siuming
    Liao, Guangxuan
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 994 - 999
  • [48] POOL OF SPRAYING AND DUSTING EQUIPMENT
    不详
    NATURE, 1955, 175 (4445) : 63 - 64
  • [49] Experimental and numerical simulation studies on heat transfer to calorimeters engulfed in diesel pool fires
    Siddapureddy, Sudheer
    Prabhu, S. V.
    JOURNAL OF FIRE SCIENCES, 2017, 35 (02) : 156 - 176
  • [50] STANDARD FOR THE PROTECTION OF ELECTRONIC-COMPUTER EQUIPMENT - NATL-FIRE-PROTECT-ASSOC
    GOODWIN, PB
    DATA PROCESSING, 1962, 4 (10): : 64 - 64