Lead isotope ratio analysis of bullet samples by using quadrupole ICP-MS

被引:3
|
作者
Tamura, Shu-ichi
Hokura, Akiko
Oishi, Masahiro
Nakai, Izumi
机构
[1] Tokyo Univ Sci, Fac Sci, Dept Appl Chem, Shinjuku Ku, Tokyo 1628601, Japan
[2] TDK Co, Ctr Mat Anal, Ichikawa, Chiba 2728558, Japan
关键词
bullet samples; lead Isotope ratio analysis; forensic identification; quadrupole ICP-MS;
D O I
10.2116/bunsekikagaku.55.827
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement conditions for the precise analysis of the lead stable isotope ratio by using an ICP-MS equipped with a quadrupole mass spectrometer were studied in order to apply the technique to the forensic identification of bullet samples. The values of the relative standard deviation obtained for the ratio of Pb-208/Ph-206, Pb-207/Pb-206 and Pb-204/Pb-206 were lower than 0.2% after optimization of the analytical conditions, including the optimum lead concentration of the sample solution to be about 70 ppb and an integration time for I m/z of 15 s. This method was applied to an analysis of lead in bullets for rifles and handguns; a stable isotope ratio of lead was found to be suitable for the identification of bullets. This study has demonstrated that the lead isotope ratio measured by using a quadrupole ICP-MS was useful for a practical analysis of bullet samples in forensic science.
引用
收藏
页码:827 / 834
页数:8
相关论文
共 50 条
  • [21] Comparison of interface cones for analysis of sodium-rich samples using quadrupole ICP-MS
    Brenner, Isaac
    Pacheco, Jaime
    Valiente, Manuel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1558 - 1563
  • [22] A lead isotope distribution study in swine tissue using ICP-MS
    May, TW
    Wiedmeyer, RH
    Brown, LD
    Casteel, SW
    ATOMIC SPECTROSCOPY, 1999, 20 (06) : 199 - 211
  • [23] Analysis of cadmium and lead in sediment by isotope-dilution ICP-MS
    Inagaki, K
    Takatsu, A
    Nakama, A
    Uchiumi, A
    Okamoto, K
    BUNSEKI KAGAKU, 2001, 50 (12) : 829 - 835
  • [24] Recent applications on isotope ratio measurements by ICP-MS and LA-ICP-MS on biological samples and single particles
    Becker, J. Sabine
    Sela, Hagit
    Dobrowolska, Justina
    Zoriy, Miroslav
    Becker, J. Susanne
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 270 (1-2) : 1 - 7
  • [25] MULTIELEMENT ANALYSIS OF WINE SAMPLES USING ICP-MS
    STROH, A
    BRUCKNER, P
    VOLLKOPF, U
    ATOMIC SPECTROSCOPY, 1994, 15 (02) : 100 - 106
  • [26] ICP-MS determination of lead isotope ratios in legal and counterfeit cigarette tobacco samples
    Judd, Christopher D.
    Swami, Kamal
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2010, 46 (04) : 484 - 494
  • [27] Precise and accurate isotope ratio measurements by ICP-MS
    Becker, JS
    Dietze, HJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01): : 23 - 30
  • [28] Precise and accurate isotope ratio measurements by ICP-MS
    J. Sabine Becker
    Hans-Joachim Dietze
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 23 - 30
  • [29] Precise isotope analysis of natural and enriched osmium samples using different ICP-MS instruments
    Boulyga, SF
    Segal, I
    Platzner, TI
    Halicz, L
    Becker, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (03) : 245 - 253
  • [30] COMPARISON OF QUADRUPOLE ICP-MS AND MAGNETIC-SECTOR ICP-MS FOR THE ANALYSIS OF U-TH SERIES ISOTOPES IN NATURAL SAMPLES
    SHAW, TJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 105 - NUCL