Extended collimator model for pencil-beam dose calculation in proton radiotherapy

被引:29
|
作者
Kanematsu, Nobuyuki
Akagi, Takashi
Takatani, Yasuyuki
Yonai, Shunsuke
Sakamoto, Hidenobu
Yamashita, Haruo
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Hyogo Ion Beam Med Ctr, Tatsuno, Hyogo 6705165, Japan
[3] Mitsubishi Electr Corp, Hyogo Ku, Kobe, Hyogo 6528555, Japan
[4] Shizuoka Canc Ctr, Shizuoka 4118777, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 19期
关键词
D O I
10.1088/0031-9155/51/19/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a simple collimator model to improve the accuracy of penumbra behaviour in pencil-beam dose calculation for proton radiotherapy. In this model, transmission of particles through a three-dimensionally extended opening of a collimator is calculated in conjunction with phase-space distribution of the particles. Comparison of the dose distributions calculated using the new three-dimensional collimator model and the conventional two-dimensional model to lateral dose profiles experimentally measured with collimated proton beams showed the superiority of the new model over the conventional one.
引用
收藏
页码:4807 / 4817
页数:11
相关论文
共 50 条
  • [31] Pencil-beam scanning proton therapy for anal cancer: a dosimetric comparison with intensity-modulated radiotherapy
    Ojerholm, Eric
    Kirk, Maura L.
    Thompson, Reid F.
    Zhai, Huifang
    Metz, James M.
    Both, Stefan
    Ben-Josef, Edgar
    Plastaras, John P.
    ACTA ONCOLOGICA, 2015, 54 (08) : 1209 - 1217
  • [32] Single Imager Proton Radiography with a Pencil-Beam Scanning System
    Harms, J.
    Maloney, L.
    Lin, Y.
    Liu, T.
    Erickson, A.
    Zhang, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E659 - E660
  • [33] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [34] Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
    Egashira, Y.
    Nishio, T.
    Hotta, K.
    Kohno, R.
    Uesaka, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04): : 1169 - 1184
  • [35] Use of pencil-beam redefinition algorithm for electron are dose calculations
    Chi, P
    Boyd, R
    Hogstrom, K
    MEDICAL PHYSICS, 2003, 30 (06) : 1518 - 1518
  • [36] Comparison of Dose Distributions for Spot-Scanned Pencil-Beam and Scattered-Beam Proton Treatments of Ocular Tumors
    Deisher, A.
    Whitaker, T.
    Kooy, H.
    Trofimov, A.
    Kruse, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 327 - 327
  • [37] Improving the Uniqueness of Numerically Extracted Proton Pencil-Beam Energy Spectrum from Integral Depth Dose
    Yao, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [38] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubes, Jiri
    Vondracek, Vladimir
    Andrlik, Michal
    Navratil, Matej
    Slavikova, Silvia
    Vitek, Pavel
    Dedeckova, Katerina
    Prausova, Jana
    Ondrova, Barbora
    Rotnaglova, Eliska
    Lukes, Petr
    Patzelt, Matej
    Grebenyuk, Alexander
    Rosina, Jozef
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (03) : 763 - 769
  • [39] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubeš Jiří
    Vondráček Vladimír
    Andrlik Michal
    Navrátil Matěj
    Sláviková Silvia
    Vítek Pavel
    Dědečková Kateřina
    Prausová Jana
    Ondrová Barbora
    Rotnáglová Eliška
    Lukeš Petr
    Patzelt Matěj
    Grebenyuk Alexander
    Rosina Jozef
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 763 - 769
  • [40] Dose Calculation Algorithm for External Neutron Radiotherapy Based On Pencil Beam Method
    Moiseev, A.
    Klimanov, V.
    MEDICAL PHYSICS, 2012, 39 (06) : 3830 - 3830