The GeMSE facility for low-background γ-ray spectrometry

被引:12
|
作者
von Sivers, M. [1 ]
Hofmann, B. A. [2 ,3 ]
Rosen, A. V. [2 ]
Schumann, M. [1 ,4 ]
机构
[1] Univ Bern, Albert Einstein Ctr Fundamental Phys, CH-3012 Bern, Switzerland
[2] Univ Bern, Inst Geol Sci, CH-3012 Bern, Switzerland
[3] Nat Hist Museum Bern, CH-3005 Bern, Switzerland
[4] Univ Freiburg, Inst Phys, D-79104 Freiburg, Germany
来源
关键词
Gamma detectors (scintillators; CZT; HPG; HgI etc); Spectrometers;
D O I
10.1088/1748-0221/11/12/P12017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a new high-purity germanium (HPGe) detector setup for low-background gamma-ray spectrometry. The GeMSE facility (Germanium Material and meteorite Screening Experiment) is dedicated to material screening for rare event searches in astroparticle physics as well as to the characterization of meteorites. It is installed in a medium depth (similar to 620 m. w. e.) underground laboratory in Switzerland in a multi-layer shielding and is equipped with an active muon veto. We have reached a very competitive integral background rate of (246 +/- 2) counts/day (100-2700 keV) and measured a sensitivity of similar to 0.5-0.6 mBq/kg for long-lived isotopes from the U-238/Th-232 chains in a similar to 1 kg sample screened for similar to 27 days. An extrapolation to higher sample masses and measurement times suggests a maximum sensitivity in the O (50) mu Bq/kg range. We describe the data analysis based on Bayesian statistics, background simulations, the efficiency calibration and first sample measurements.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] A second-generation low-background gamma-ray spectrometer
    Lindstrom, Richard M.
    APPLIED RADIATION AND ISOTOPES, 2017, 126 : 191 - 193
  • [42] Detection of background thermal neutrons in a modified low-background germanium gamma-ray spectrometer
    Mietelski, Jerzy W.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (03) : 1331 - 1339
  • [43] Detection of background thermal neutrons in a modified low-background germanium gamma-ray spectrometer
    Jerzy W. Mietelski
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 322 : 1331 - 1339
  • [44] Experimental study of the integral background of a low-background anti-Compton HPGe γ-ray spectrometer
    Zhou Chunlin
    Xu Zhenhua
    Xu Congxue
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 649 - 653
  • [45] Installation of a muon veto for low background gamma spectroscopy at the LBNL low-background facility (vol 724, pg 47, 2013)
    Thomas, K. J.
    Norman, E. B.
    Smith, A. R.
    Chan, Y. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 736 : 204 - 204
  • [46] LOW-BACKGROUND GAS-FILLED ELECTRON AND X-RAY COUNTERS
    KOCHAROV, GE
    NAIDENOV, VO
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (03): : 515 - &
  • [47] MEGA: A low-background radiation detector
    Kazkaz, K
    Aalseth, CE
    Hossbach, TW
    Gehman, VM
    Kephart, JD
    Miley, HS
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 87 - 91
  • [48] LOW-BACKGROUND COUNTING SYSTEMS COMPARED
    MILEY, HS
    BRODZINSKI, RL
    REEVES, JH
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 160 (02): : 371 - 385
  • [49] Determination of low-level 54Mn in soils by ultra low-background gamma-ray spectrometry after radiochemical separation
    Y. Murata
    M. Yamamoto
    K. Komura
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 254 : 249 - 253
  • [50] Determination of low-level 54Mn in soils by ultra low-background gamma-ray spectrometry after radiochemical separation
    Murata, Y
    Yamamoto, M
    Komura, K
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 254 (02) : 249 - 253