Histogram error based algorithm for efficient collimation testing

被引:1
|
作者
Dhanotia, Jitendra [1 ]
Bande, Shivangi [2 ]
Bhatia, Vimal [1 ]
Prakash, Shashi [2 ]
机构
[1] Indian Inst Technol Indore, Discipline Elect Engn, Signals & Software Grp, Indore 453552, Madhya Pradesh, India
[2] Devi Ahilya Univ, Inst Engn & Technol, Dept Elect & Instrumentat Engn, Photon Lab, Khandwa Rd, Indore 452017, Madhya Pradesh, India
关键词
collimation; interferometry; self-imaging phenomena; metrology; SMALL INCLINATION MISALIGNMENT; ARBITRARY LINE ORIENTATION; TALBOT INTERFEROMETRY; SETTING SENSITIVITY; GRATINGS;
D O I
10.1088/2040-8986/ab3870
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This communication reports an investigation undertaken towards setting collimation of an optical beam using a self-imaging technique and histogram error (HE) based approach. The beam under test illuminates an amplitude type Ronchi grating. After the grating, a beam splitter is placed such that the grating's self-images are formed in two perpendicular directions, at the different Talbot planes. The images are then recorded using two identical CCD cameras. Towards implementing a HE based algorithm, first, element-by-element subtraction of the normalized histogram of both self-images is computed. Next, the sum of the elements of the resultant image matrix is determined. Finally, the square of the sum yields the HE. HE provides an estimate of the collimation errors in the beam. For an incident collimated beam, the self-images recorded at different Talbot planes have identical unit magnification with respect to the grating; however, when the beam diverges or converges, the size and fringe width of self-images are differentially magnified or demagnified. Hence, when the beam is collimated, the HE is minimum. For the decollimated beam, the value of HE is higher, and increases as the decollimation errors increase. Using the proposed method, we could set the collimation position to a resolution of 1 mu m, which relates to +/- 0.22 mu radians in terms of collimation angle (for a lens of focal length 300 mm and diameter 40 mm). Experimental results conclusively establish the viability of the technique. Good accuracy and precision in the measurement have been achieved.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Self-imaging-based laser collimation testing technique
    Mudassar, Asloob A.
    Butt, Saira
    APPLIED OPTICS, 2010, 49 (31) : 6057 - 6062
  • [42] Data Balance Algorithm Based on Histogram in MapReduce
    Zhou W.
    Zhong Y.
    Wang Y.
    2018, Northwestern Polytechnical University (36): : 480 - 486
  • [43] THE COLLIMATION ERROR OF THE AIRY TRANSIT CIRCLE
    GETHING, PJD
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1954, 114 (04) : 415 - 432
  • [44] Collimation testing with circular gratings
    Shakher, C
    Prakash, S
    Nand, D
    Kumar, R
    APPLIED OPTICS, 2001, 40 (08) : 1175 - 1179
  • [45] Collimation testing techniques: A review
    Sirohi, RS
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 292 - 293
  • [46] Testing of dynamic multileaf collimation
    Chui, CS
    Spirou, S
    LoSasso, T
    MEDICAL PHYSICS, 1996, 23 (05) : 635 - 641
  • [47] IMPROVED TECHNIQUES OF COLLIMATION TESTING
    KOTHIYAL, MP
    SIROHI, RS
    ROSENBRUCH, KJ
    OPTICS AND LASER TECHNOLOGY, 1988, 20 (03): : 139 - 144
  • [48] Collimation testing with circular gratings
    Shakher, Chandra
    Prakash, Shashi
    Nand, Daya
    Kumar, Rajesh
    Applied Optics, 2001, 40 (08): : 1175 - 1179
  • [49] Improved collimation testing technique
    Mudassar, Asloob Ahmad
    Butt, Saira
    APPLIED OPTICS, 2012, 51 (26) : 6429 - 6440
  • [50] The application of PSD in the collimation testing
    Zhang, Z
    Jiao, LH
    Hu, XD
    SMART MATERIALS, STRUCTURES, AND INTEGRATED SYSTEMS, 1997, 3241 : 408 - 416