Full-Scale Measurements and System Identification on Sutong Cable-Stayed Bridge during Typhoon Fung-Wong

被引:13
|
作者
Wang, Hao [1 ]
Tao, Tianyou [2 ]
Guo, Tong [1 ]
Li, Jian [3 ]
Li, Aiqun [1 ]
机构
[1] Southeast Univ, Key Lab C&PC Struct, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Sch Civil Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] Univ Kansas, Dept Civil Environm & Architectural Engn, Lawrence, KS 66045 USA
来源
基金
美国国家科学基金会;
关键词
WIND-INDUCED VIBRATIONS; SUSPENSION BRIDGE; GPS;
D O I
10.1155/2014/936832
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The structural health monitoring system (SHMS) provides an effective tool to conduct full-scale measurements on existing bridges for essential research on bridge wind engineering. In July 2008, Typhoon Fung-Wong lashed China and hit Sutong cable-stayed bridge (SCB) in China. During typhoon period, full-scale measurements were conducted to record the wind data and the structural vibration responses were collected by the SHMS installed on SCB. Based on the statistical method and the spectral analysis technique, the measured data are analyzed to obtain the typical parameters and characteristics. Furthermore, this paper analyzed the measured structural vibration responses and indicated the vibration characteristics of the stay cable and the deck, the relationship between structural vibrations and wind speed, the comparison of upstream and downstream cable vibrations, the effectiveness of cable dampers, and so forth. Considering the significance of damping ratio in vibration mitigation, the modal damping ratios of the SCB are identified based on the Hilbert-Huang transform (HHT) combined with the random decrement technique (RDT). The analysis results can be used to validate the current dynamic characteristic analysis methods, buffeting calculation methods, and wind tunnel test results of the long-span cable-stayed bridges.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Full-scale measurements on buffeting response of Sutong Bridge under typhoon Fung-Wong
    Wang, H.
    Li, A. Q.
    Zhu, T. Y.
    Hu, R. M.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE-CYCLE OPTIMIZATION, 2010, : 878 - +
  • [2] Nonstationary characteristics of Typhoon Fung-Wong observed at Sutong Bridge site based on SHMS
    Wang, H.
    Tao, T. Y.
    Zhang, Y. P.
    Li, A. Q.
    MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 255 - 255
  • [3] Modal Identification of Sutong Cable-Stayed Bridge during Typhoon Haikui Using Wavelet Transform Method
    Wang, H.
    Mao, J. X.
    Huang, J. H.
    Li, A. Q.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (05)
  • [4] Evaluation of buffeting predictions of a cable-stayed bridge from full-scale measurements
    Macdonald, JHG
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2003, 91 (12-15) : 1465 - 1483
  • [5] Full-scale dynamic testing of a repaired cable-stayed bridge
    Gentile, C
    Cabrera, FMY
    STRUCTURAL DYNAMICS, VOLS. 1 & 2, 1996, : 809 - 816
  • [6] Structural health monitoring system for Sutong Cable-stayed Bridge
    Wang, Hao
    Tao, Tianyou
    Li, Aiqun
    Zhang, Yufeng
    SMART STRUCTURES AND SYSTEMS, 2016, 18 (02) : 317 - 334
  • [7] Full-scale dynamic testing of the Alamillo cable-stayed bridge in Sevilla (Spain)
    Technical Univ of Catalunya, Barcelona, Spain
    Earthquake Eng Struct Dyn, 1 (35-51):
  • [8] Full-scale Model Test for Anchorage Zone of Pylon of Cable-stayed Bridge
    Yu, Xiaolin
    Jia, Buyu
    Wang, Weifeng
    Yan, Quansheng
    INNOVATION IN CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE, 2012, 238 : 728 - 732
  • [9] FULL-SCALE DYNAMIC TESTING OF THE ALAMILLO CABLE-STAYED BRIDGE IN SEVILLE (SPAIN)
    CASAS, JR
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1995, 24 (01): : 35 - 51
  • [10] COMPARISON OF FULL-SCALE MEASUREMENT AND COMPUTATION OF WIND EFFECTS ON A CABLE-STAYED BRIDGE
    BIETRY, J
    DELAUNAY, D
    CONTI, E
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1995, 57 (2-3) : 225 - 235