Fracture strength of various titanium-based, CAD-CAM and PFM implant crowns

被引:7
|
作者
DuVall, Nicholas B. [1 ,2 ]
DeReis, Stephen P. [3 ]
Vandewalle, Kraig S. [2 ,4 ]
机构
[1] 96th Dent Squadron, AEGD Residency, Eglin AFB, FL USA
[2] Uniformed Serv Univ Hlth Sci, US Air Force Postgrad Dent Coll, Bethesda, MD 20814 USA
[3] 81st Dent Squadron, Keesler AFB, MS USA
[4] 59th Dent Training Squadron, AEGD Residency, Joint Base San Antonio L, TX USA
关键词
abutment; CAD‐ CAM; cement‐ retained; implant restoration; screw‐ TiBase; LITHIUM DISILICATE; CLINICAL-OUTCOMES; SINGLE CROWNS; ABUTMENTS; PERFORMANCE; RECONSTRUCTIONS; COMPLICATIONS; RESTORATIONS; SURVIVAL; FAILURE;
D O I
10.1111/jerd.12672
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective CAD-CAM has dramatically advanced dental restorative procedures to include implant-supported crowns. The purpose of this study was to compare the fracture resistance following mechanical loading and thermocycling of various screw-retained and cement-retained ceramic and polymethylmethacrylate material combinations using the TiBase abutment compared to PFM implant-supported crowns. Overview Twelve implant restorations were fabricated for each of eight groups. Three groups were screw-retained and five groups were cement-retained implant restorations. The ceramic and polymethylmethacrylate restorations were fabricated on the TiBase abutment while the PFM restorations were fabricated on an UCLA abutment. Data were analyzed with a one way Analysis of Variance and Tukey's post-hoc test to evaluate the effect of abutment and crown type on fracture load (alpha = 0.05). A significant difference was found in the maximum fracture load between groups (P < 0.001). Conclusions The screw-retained implant restorations demonstrated higher fracture loads than their cement-retained counterparts. The TiBase abutment compared favorably to the UCLA abutment. Clinical Significance The TiBase abutment is a titanium insert which combines the esthetics of a ceramic abutment with the mechanical properties of a titanium abutment and should be considered a viable clinical alternative to the conventional implant-supported PFM crown based on theses in vitro results and in context of in vivo studies. The lithium disilicate hybrid abutment/crown implant-supported restoration utilizing the TiBase abutment may be an ideal clinical choice due to simplicity, single appointment CAD-CAM, and esthetics.
引用
收藏
页码:522 / 530
页数:9
相关论文
共 50 条
  • [31] Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns
    Bindl, A
    Lüthy, H
    Mörmann, WH
    DENTAL MATERIALS, 2006, 22 (01) : 29 - 36
  • [32] Fracture Load of Monolithic CAD/CAM Ceramic Crowns Placed on Different Implant Abutments
    Meneghetti, Priscila Ceolin
    Pittas do Canto, Paulo Eduardo
    Spohr, Ana Maria
    Burnett Junior, Luiz Henrique
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1217 - 1222
  • [33] Immediate implant placement and complete mouth rehabilitation with CAD-CAM titanium frameworks and cemented crowns for a patient with severe periodontal disease: A clinical report
    Wang, Pei
    Tang, Chunbo
    Tang, Yi
    Wu, Yunong
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04): : 511 - 515
  • [34] Fracture strength of preformed zirconia crown and CAD-CAM zirconia, ceramic, and hybrid composite crowns for the restoration of primary molars: An in vitro study
    El Hayek, Joy Elian
    Tohme, Hani
    Nasr, Lara
    El Hachem, Roula
    Kabbani, Nathalie
    Mchayleh, Nada Farhat
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2024, 34 (06) : 721 - 728
  • [35] In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness
    Sorrentino, Roberto
    Triulzio, Clementina
    Tricarico, Maria Gabriella
    Bonadeo, Giovanni
    Gherlone, Enrico Felice
    Ferrari, Marco
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 328 - 333
  • [36] CAD/CAM Technology for Implant Abutments, Crowns, and Superstructures
    Kapos, Theodoros
    Evans, Christopher
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 : 117 - 136
  • [37] Evaluation of the Fatigue Strength of a CAD-CAM Nanoceramic Resin Crown on Titanium and Zirconia-Titanium Abutments
    Graiff, Lorenzo
    Savio, Gianpaolo
    Di Fiore, Adolfo
    Rosso, Stefano
    Meneghello, Roberto
    Uccheddu, Francesca
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [38] The effect of different deep margin elevation methods on the fracture strength of CAD-CAM restorations
    Balci, Seyma Nilgun
    Tekce, Neslihan
    Tuncer, Safa
    Demirci, Mustafa
    AMERICAN JOURNAL OF DENTISTRY, 2024, 37 (03): : 115 - 120
  • [39] Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns
    Kwon, Taek-Ka
    Pak, Hyun-Soon
    Yang, Jae-Ho
    Han, Jung-Suk
    Lee, Jai-Bong
    Kim, Sung-Hun
    Yeo, In-Sung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (02): : 92 - 97
  • [40] In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns
    Martin Rosentritt
    Sebastian Hahnel
    Frank Engelhardt
    Michael Behr
    Verena Preis