Transcritical CO2 heat pump dryer:: Part 1.: Mathematical model and simulation

被引:34
|
作者
Sarkar, J. [1 ]
Bhattacharyya, Souvik [1 ]
Gopal, M. Ram [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
关键词
CO2 heat pump; heat pump dryer; mathematical modeling; simulation;
D O I
10.1080/07373930601030903
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, a mathematical model and simulation code has been developed to investigate the performance of a transcritical CO2 heat pump dryer. The model takes into account detailed heat and mass transfer and pressure drop phenomena occurring in each component of the system. To take care of the variable heat transfer properties, the heat exchanger components were divided into several infinitesimal segments to examine the state, heat and mass balance and pressure drop for both refrigerant and air, and hence accurate results are expected. In Part 2 of the article, the model developed has been validated with experimental data and then the model was used to investigate effects of important operating parameters on the performance.
引用
收藏
页码:1583 / 1591
页数:9
相关论文
共 50 条
  • [31] SYSTEM ANALYSIS AND OPTIMIZATION OF A CO2 HEAT PUMP TUMBLE DRYER
    Alpoegger, Thomas
    Tegethoff, Wilhelm
    Bockholt, Marcos
    Bussmann, Ralf
    Koehler, Juergen
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 642 - 649
  • [32] Development and validation of static simulation model for CO2 heat pump
    Yamaguchi, Seiichi
    Kato, Daisuke
    Saito, Kiyoshi
    Kawai, Sunao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (9-10) : 1896 - 1906
  • [33] A transcritical CO2 heat pump for simultaneous water cooling and heating: Test results and model validation
    Sarkar, J.
    Bhattacharyya, Souvik
    Ramgopal, M.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (01) : 100 - 109
  • [34] Bi-objective optimization of transcritical CO2 heat pump systems
    Okasha, Ahmed
    Mueller, Norbert
    Deb, Kalyanmoy
    ENERGY, 2022, 247
  • [35] Effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump
    Cho, HY
    Ryu, CG
    Kim, YC
    Kim, HY
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1266 - 1273
  • [36] Energy and Exergy Analysis of Transcritical CO2 Cycles for Heat Pump Applications
    Gambini, Marco
    Manno, Michele
    Vellini, Michela
    SUSTAINABILITY, 2024, 16 (17)
  • [37] Optimization of ejector-expansion transcritical CO2 heat pump cycle
    Sarkar, Jahar
    ENERGY, 2008, 33 (09) : 1399 - 1406
  • [38] Model predictive control for the operation of a transcritical CO2 air source heat pump water heater
    Wang, Wenyi
    Zhao, Zhongfan
    Zhou, Qun
    Qiao, Yiyuan
    Cao, Feng
    APPLIED ENERGY, 2021, 300
  • [39] Experimental study of key parameter on transcritical CO2 heat pump system
    Zhu, Zhi-Jiang
    Chen, Guang-Ming
    Tong, Yang
    Tang, Li-Ming
    Lin, Shun-Rong
    Chen, Qi
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2011, 32 (07): : 1103 - 1106
  • [40] DEVELOPMENT AND VALIDATION OF VARIABLE FREQUENCY TRANSCRITICAL CO2 HEAT PUMP SYSTEMS
    Chen, Q.
    Qi, H. M.
    Tang, L. M.
    Wei, J.
    Chen, G. M.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 614 - 621