A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls

被引:49
|
作者
van Vlijmen, Olivier J. C. [1 ,2 ]
Maal, Thomas J. J. [2 ,3 ]
Berge, Stefaan J. [2 ,3 ]
Bronkhorst, Ewald M. [4 ]
Katsaros, Christos [1 ,5 ]
Kuijpers-Jagtman, Anne Marie [1 ,2 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, NL-6500 HB Nijmegen, Netherlands
[2] 3D Facial Imaging Res Grp Nijmegen Bruges 3D FIRG, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Oral & Maxillofacial Surg, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Dept Prevent & Curat Dent, NL-6500 HB Nijmegen, Netherlands
[5] Univ Bern, Dept Orthodont & Dentofacial Orthoped, Bern, Switzerland
关键词
cephalometry; cone beam computed tomography; maxillofacial; orthodontics; three-dimensional imaging; MAXILLOFACIAL RADIOLOGY; CBCT DEVICES; CT; DOSIMETRY; ACCURACY;
D O I
10.1111/j.1600-0722.2009.00633.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were made of 40 dry human skulls. From the CBCT scan a 3D model was constructed. Standard cephalometric software was used to identify landmarks and to calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs, and on all images, five times with a time interval of 1 wk. Intra-observer reliability was acceptable for all measurements. There was a statistically significant and clinically relevant difference between measurements performed on conventional frontal radiographs and on 3D CBCT-derived models of the same skull. There was a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements performed on 3D models constructed from CBCT scans. We therefore recommend that 3D models should not be used for longitudinal research in cases where there are only two-dimensional (2D) records from the past.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [41] Three-dimensional imaging and osteometry of adult human skulls using helical computed tomography
    M. Nagashima
    K. Inoue
    T. Sasaki
    K. Miyasaka
    G. Matsumura
    G. Kodama
    Surgical and Radiologic Anatomy, 1998, 20 : 291 - 297
  • [42] Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography
    Nakajima, A
    Sameshima, GT
    Arai, Y
    Homme, Y
    Shimizu, N
    Dougherty, H
    ANGLE ORTHODONTIST, 2005, 75 (06) : 895 - 903
  • [43] Reliability of classification of ring and little finger carpometacarpal joint fracture subluxations: a comparison between two-dimensional computed tomography and three-dimensional computed tomography classifications
    Kim, J. H.
    Kwon, S. -S.
    Moon, S. J.
    Choe, J. S.
    Kwak, H. I.
    Lee, S. Y.
    Le, H. J.
    Kim, J. Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2016, 41 (04) : 448 - 452
  • [44] No correlation between two-dimensional measurements and three-dimensional configuration of the pharyngeal upper airway space in cope-beam computed tomography
    Abe-Nickler, Marie Dorothee
    Poertner, Samira
    Sieg, Peter
    Hakim, Samer George
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (03) : 371 - 376
  • [45] Comparison of three-dimensional and two-dimensional computed tomographies in the classification of acetabular fractures
    Kanthawang, Thanat
    Vaseenon, Tanawat
    Sripan, Patumrat
    Pattamapaspong, Nuttaya
    EMERGENCY RADIOLOGY, 2020, 27 (02) : 157 - 164
  • [46] Comparison of three-dimensional and two-dimensional computed tomographies in the classification of acetabular fractures
    Thanat Kanthawang
    Tanawat Vaseenon
    Patumrat Sripan
    Nuttaya Pattamapaspong
    Emergency Radiology, 2020, 27 : 157 - 164
  • [47] Two-dimensional and three-dimensional computed tomography for the classification and characterisation of tibial plateau fractures
    Doornberg, Job N.
    Rademakers, Maarten V.
    van den Bekerom, Michel P.
    Kerkhoffs, Gino M.
    Ahn, Jaimo
    Steller, E. Ph.
    Kloen, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (12): : 1416 - 1425
  • [48] Comparison of two-dimensional imaging to three-dimensional modeling of intrahepatic portosystemic shunts using computed tomography angiography
    Jackson, Erin
    Markovic, Lauren E.
    Perlini, Michael
    VETERINARY RADIOLOGY & ULTRASOUND, 2024, 65 (02) : 130 - 137
  • [49] Three-dimensional cone beam computerized tomography in orthodontics
    Kau, C. H.
    Richmond, S.
    Palomo, J. M.
    Hans, M. G.
    JOURNAL OF ORTHODONTICS, 2005, 32 (04) : 282 - 293
  • [50] Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques
    Guo, Jie
    Qian, Jiang
    Yuan, Yifei
    CURRENT EYE RESEARCH, 2018, 43 (05) : 647 - 653