A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls

被引:49
|
作者
van Vlijmen, Olivier J. C. [1 ,2 ]
Maal, Thomas J. J. [2 ,3 ]
Berge, Stefaan J. [2 ,3 ]
Bronkhorst, Ewald M. [4 ]
Katsaros, Christos [1 ,5 ]
Kuijpers-Jagtman, Anne Marie [1 ,2 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, NL-6500 HB Nijmegen, Netherlands
[2] 3D Facial Imaging Res Grp Nijmegen Bruges 3D FIRG, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Oral & Maxillofacial Surg, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Dept Prevent & Curat Dent, NL-6500 HB Nijmegen, Netherlands
[5] Univ Bern, Dept Orthodont & Dentofacial Orthoped, Bern, Switzerland
关键词
cephalometry; cone beam computed tomography; maxillofacial; orthodontics; three-dimensional imaging; MAXILLOFACIAL RADIOLOGY; CBCT DEVICES; CT; DOSIMETRY; ACCURACY;
D O I
10.1111/j.1600-0722.2009.00633.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were made of 40 dry human skulls. From the CBCT scan a 3D model was constructed. Standard cephalometric software was used to identify landmarks and to calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs, and on all images, five times with a time interval of 1 wk. Intra-observer reliability was acceptable for all measurements. There was a statistically significant and clinically relevant difference between measurements performed on conventional frontal radiographs and on 3D CBCT-derived models of the same skull. There was a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements performed on 3D models constructed from CBCT scans. We therefore recommend that 3D models should not be used for longitudinal research in cases where there are only two-dimensional (2D) records from the past.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
  • [1] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans
    Michele, Cassetta
    Federica, Altieri
    Roberto, Di Giorgio
    Alessandro, Silvestri
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) : E311 - E315
  • [2] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans (vol 26, pg e311, 2015)
    Cassetta, Michele
    Altieri, Federica
    Di Giorgio, Roberto
    Silvestri, Alessandro
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (06) : e560 - e560
  • [3] A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls
    van Vlijmen, O. J. C.
    Berge, S. J.
    Bronkhorst, E. M.
    Swennen, G. R. J.
    Katsaros, C.
    Kuijpers-Jagtman, A. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (07) : 773 - 778
  • [4] Preliminary evaluation of cone beam computed tomography in three-dimensional cephalometry for clinical application
    Li, Na
    Hu, Bo
    Mi, Fanglin
    Song, Jinlin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (05) : 2451 - 2455
  • [5] Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
    Almpani, Konstantinia
    Adjei, Anna
    Liberton, Denise K.
    Verma, Payal
    Hung, Man
    Lee, Janice S.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (199):
  • [6] Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls
    Damstra, Janalt
    Fourie, Zacharias
    Ren, Yijin
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2011, 49 (05): : 392 - 395
  • [7] The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements
    Tchorz, J. P.
    Poxleitner, P. J.
    Stampf, S.
    Patzelt, S. B. M.
    Rottke, D.
    Hellwig, E.
    Altenburger, M. J.
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (04) : 1129 - 1133
  • [8] The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements
    J. P. Tchorz
    P. J. Poxleitner
    S. Stampf
    S. B. M. Patzelt
    D. Rottke
    E. Hellwig
    M. J. Altenburger
    Clinical Oral Investigations, 2014, 18 : 1129 - 1133
  • [9] Consistency and precision of landmark identification in three-dimensional cone beam computed tomography scans
    Schlicher, Will
    Nielsen, Ib
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, A. J.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (03) : 263 - 275
  • [10] Evaluation of two-dimensional lateral cephalogram and three-dimensional cone beam computed tomography superimpositions: a comparative study
    Heinz, J.
    Stewart, K.
    Ghoneima, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (04) : 519 - 525