Helical cone-beam tomography

被引:1
|
作者
Turbell, H [1 ]
Danielsson, PE [1 ]
机构
[1] Linkoping Univ, Dept Elect Engn, Image Proc Lab, SE-58183 Linkoping, Sweden
关键词
D O I
10.1002/(SICI)1098-1098(2000)11:1<91::AID-IMA10>3.0.CO;2-F
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, several computed tomography (CT) machines with multirow detectors have been introduced on the market. Although the projections are obtained from a cone beam rather than a fan beam, multislice reconstruction algorithms in contemporary machines are firmly rooted in two-dimensional (2D) reconstruction of planar objects. Short-scan algorithms are dominating and these are preferably classified according to how redundant data are handled, using parallel rebinning, complementary rebinning, or Parker weighting. In the long run, truly 3D cone-beam algorithms are likely to take over, however. It has proved to be quite a challenge to design an algorithm that is both practical and exact under the constraints set by helical source path geometry. All attempts in this direction are readily seen to be derivatives of Grangeat's algorithm. Alternative research efforts have been building on the nonexact algorithm by Feldkamp et al. (J Opt Soc Am 1: 612-619, 1984). These algorithms strive for simplicity using 1D filtering only. In this overview, we pay special attention to the PI method, which has the unique property that all object points are illuminated by the source during exactly 180 degrees, which generates complete and nonredundant data. Two new algorithms, PI-SLANT and P1-2D, are also presented with some experimental results. (C) 2000 John Wiley & Sons, Inc.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 50 条
  • [31] Exact and approximate algorithms for helical cone-beam CT
    Kudo, H
    Rodet, T
    Noo, F
    Defrise, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2913 - 2931
  • [32] The frequency split method for helical cone-beam reconstruction
    Shechter, G
    Köhler, T
    Altman, A
    Proksa, R
    MEDICAL PHYSICS, 2004, 31 (08) : 2230 - 2236
  • [33] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [34] Exact Efficient Handling of Interrupted Illumination in Helical Cone-Beam Computed Tomography with Arbitrary Pitch
    Harald Schndube
    Karl Stierstorfer
    Frédéric Noo
    TsinghuaScienceandTechnology, 2010, 15 (01) : 36 - 43
  • [35] Three-dimensional helical-scan computed tomography using cone-beam projections
    Kudo, Hiroyuki
    Saito, Tsuneo
    Systems and Computers in Japan, 1992, 23 (12) : 75 - 82
  • [36] Cone-beam pseudo-lambda tomography
    Ye, Yangbo
    Yu, Hengyong
    Wang, Ge
    INVERSE PROBLEMS, 2007, 23 (01) : 203 - 215
  • [37] Cone-beam computerized tomography and the transverse dimension
    Flores-Mir, Carlos
    SEMINARS IN ORTHODONTICS, 2013, 19 (03) : 204 - 209
  • [39] Noise performance of fast hierarchical 3D backprojection for helical cone-beam tomography
    Brokish, Jeffrey
    Bresler, Yoram
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1860 - 1862
  • [40] Iterative image reconstruction for limited-angle inverse helical cone-beam computed tomography
    Yu, Wei
    Zeng, Li
    SCANNING, 2016, 38 (01) : 4 - 13