Two-Photon Excitation STED Microscopy with Time-Gated Detection

被引:26
|
作者
Hernandez, Ivan Coto [1 ,2 ,5 ]
Castello, Marco [1 ,3 ]
Lanzano, Luca [1 ]
d'Amora, Marta [1 ]
Bianchini, Paolo [1 ]
Diaspro, Alberto [1 ,2 ,4 ]
Vicidomini, Giuseppe [1 ]
机构
[1] Ist Italiano Tecnol, Nanoscopy, Nanophys, Via Morego 30, I-16163 Genoa, Italy
[2] Univ Genoa, Dept Phys, Via Dodecaneso 33, I-16146 Genoa, Italy
[3] Univ Genoa, Dept Informat Bioengn Robot & Syst Engn, Via Opera Pia 13, I-16145 Genoa, Italy
[4] Ist Italiano Tecnol, Nikon Imaging Ctr, Via Morego 30, I-16163 Genoa, Italy
[5] Univ Paris Saclay, Univ Paris 11, CNRS, Inst Sci Mol Orsay, F-91405 Orsay, France
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
关键词
STIMULATED-EMISSION-DEPLETION; RESOLUTION; NANOSCOPY; PHOTON; LIMIT;
D O I
10.1038/srep19419
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report on a novel two-photon excitation stimulated emission depletion (2PE-STED) microscope based on time-gated detection. The time-gated detection allows for the effective silencing of the fluorophores using moderate stimulated emission beam intensity. This opens the possibility of implementing an efficient 2PE-STED microscope with a stimulated emission beam running in a continuous-wave. The continuous-wave stimulated emission beam tempers the laser architecture's complexity and cost, but the time-gated detection degrades the signal-to-noise ratio (SNR) and signal-to-background ratio (SBR) of the image. We recover the SNR and the SBR through a multi-image deconvolution algorithm. Indeed, the algorithm simultaneously reassigns early-photons (normally discarded by the time-gated detection) to their original positions and removes the background induced by the stimulated emission beam. We exemplify the benefits of this implementation by imaging sub-cellular structures. Finally, we discuss of the extension of this algorithm to future all-pulsed 2PE-STED implementationd based on time-gated detection and a nanosecond laser source.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Real time two-photon absorption microscopy using multi point excitation
    Buist, AH
    Müller, M
    Squier, J
    Brakenhoff, GJ
    JOURNAL OF MICROSCOPY, 1998, 192 : 217 - 226
  • [32] Two-photon excitation microscopy for analyses of biofilm processes
    Bryers, JD
    MICROBIAL GROWTH IN BIOFILMS, PT B: SPECIAL ENVIRONMENTS AND PHYSICOCHEMICAL ASPECTS, 2001, 337 : 259 - 269
  • [33] Two-photon excitation microscopy with spatial light modulator
    Matsumoto, Naoya
    Konno, Alu
    Inoue, Takashi
    Toyoda, Haruyoshi
    Miwa, Toshiyuki
    Nakamura, Kazuhiro
    Okazaki, Shigetoshi
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [34] Pulse compression in two-photon excitation fluorescence microscopy
    Liang, Xiaobao
    Hu, Wenyan
    Fu, Ling
    OPTICS EXPRESS, 2010, 18 (14): : 14893 - 14904
  • [35] Combined optical coherence and two-photon excitation microscopy
    Beaurepaire, E
    Moreaux, L
    Mertz, J
    PROCEEDINGS OF INTER-INSTITUTE WORKSHOP ON IN VIVO OPTICAL IMAGING AT THE NIH, 2000, : 43 - 48
  • [36] Antecedents of two-photon excitation laser scanning microscopy
    Masters, BR
    So, PTC
    MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 63 (01) : 3 - 11
  • [37] Quantitative imaging of metabolism by two-photon excitation microscopy
    Piston, DW
    Knobel, SM
    CONFOCAL MICROSCOPY, 1999, 307 : 351 - 368
  • [38] Continuous wave excitation two-photon fluorescence microscopy
    Hanninen, P.E.
    Soini, E.
    Hell, S.W.
    Journal of Microscopy, 1994, 176 (03) : 222 - 225
  • [39] Time-gated confocal Ramon microscopy
    Yakovlev, Vladimir V.
    SPECTROSCOPY, 2007, 22 (10) : 34 - 41
  • [40] Non-Gaussian-state generation with time-gated photon detection
    Sonoyama, Tatsuki
    Takahashi, Kazuma
    Charoensombutamon, Baramee
    Takasu, Sachiko
    Hattori, Kaori
    Fukuda, Daiji
    Fukui, Kosuke
    Takase, Kan
    Asavanant, Warit
    Yoshikawa, Jun-ichi
    Endo, Mamoru
    PHYSICAL REVIEW RESEARCH, 2023, 5 (03):