Quantitative Evaluation of Electrical Life of AC Contactor Based on Initial Characteristic Parameters

被引:24
|
作者
Sun, Shuguang [1 ]
Wang, Qiufu [1 ]
Du, Taihang [1 ]
Wang, Jingqin [2 ]
Li, Senjuan [1 ]
Zong, Junji [1 ]
机构
[1] Hebei Univ Technol, Sch Artificial Intelligence, Tianjin 300130, Peoples R China
[2] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equip, Tianjin 300130, Peoples R China
基金
中国国家自然科学基金;
关键词
AC contactor; electrical life; initial characteristic parameter; quantitative evaluation; unitary regressive analysis; ENDURANCE PREDICTION; PROGNOSTICS; MODEL;
D O I
10.1109/TIM.2020.3031160
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In terms of estimating the ac contactor's electrical life, a new method based on initial characteristic parameters is put forward in this article. First, the characteristic parameters of the contact voltage in the closing stage and the arcing energy in the breaking stage are selected to extract their statistical indexes due to different stages in the contactor's action, and the correlation between the indexes and electrical life is calculated by means of the Spearman rank correlation coefficient. Next, the electrical life evaluation indexes corresponding to the stages of closing and breaking are computed according to the weighted Euclidean distance calculation; the electrical life comprehensive evaluation index is presented by secondary fusion of the abovementioned indexes. Finally, a life prediction model based on unitary regression is established to evaluate electrical life with the predicted input of the comprehensive evaluation index. The results have displayed that the proposed method succeeds in quantitatively evaluating the electrical life of an ac contactor.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] AC contactor reliability evaluation system based on dynamic testing
    Miao, Xiren
    Lin, Subin
    Zhang, Peiming
    Proceedings of the 2nd International Conference on Reliability of Electrical Products and Electrical Contacts, 2007, : 257 - 261
  • [12] Condition Evaluation of AC Contactor Based on The Grey Fuzzy Theory
    Liu, Shuxin
    Wang, Yuanyuan
    Liu, Zichun
    Cao, Yundong
    Zhu, Shunhua
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 238 - 242
  • [13] Failure feature extraction for electrical life prediction of AC contactor under mechanical vibration
    Sun S.
    Ji X.
    Du T.
    Hao L.
    Wang R.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (03): : 114 - 125
  • [14] Adaptive Holding Control Strategy of AC Contactor Based on Multiple Feedback Parameters
    Liu X.
    Yang C.
    Zhou Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (02): : 554 - 562
  • [15] Residual-Electrical-Endurance Prediction of AC Contactor Based on CNN-GRU
    Liu, Shuxin
    Gao, Shuyu
    Peng, Shidong
    Liu, Yang
    Li, Jing
    MACHINES, 2022, 10 (11)
  • [16] Quantitative evaluation of flowing blood with the electrical parameters based on the Hanai mixture equation
    Nakajima, Yusuke
    Kawashima, Daisuke
    Shoji, Ryubu
    Matsuura, Katsuhiro
    Takei, Masahiro
    BIORHEOLOGY, 2021, 58 (3-4) : 117 - 117
  • [17] A Control Strategy for Maximizing the Electrical Life of AC Contactors Based on Real-Time Operating Parameters
    Li K.
    Zhang G.
    Zheng S.
    Huang S.
    Zhao C.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (09): : 1976 - 1985
  • [18] Remaining Useful Life Prediction for AC Contactor Based on MMPE and LSTM With Dual Attention Mechanism
    Sun, Shuguang
    Liu, Jinfa
    Wang, Jingqin
    Chen, Fan
    Wei, Shuo
    Gao, Hui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [19] A study on life evaluation & prediction of railway vehicle contactor based on accelerated life test data
    Minheung Park
    Sehun Rhee
    Journal of Mechanical Science and Technology, 2018, 32 : 4621 - 4628
  • [20] A study on life evaluation & prediction of railway vehicle contactor based on accelerated life test data
    Park, Minheung
    Rhee, Sehun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (10) : 4621 - 4628