Determination of uncertainties in energy and exergy analysis of a power plant

被引:16
|
作者
Ege, Ahmet [1 ]
Sahin, Haci Mehmet [2 ]
机构
[1] Elect Generat Co, Dept Nucl Power Plants, TR-06520 Ankara, Turkey
[2] Gazi Univ, Fac Technol, TR-06503 Ankara, Turkey
关键词
Thermal power plant; Exergy; Uncertainty; Sensitivity; Efficiency; Energy;
D O I
10.1016/j.enconman.2014.05.088
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, energy and exergy efficiency uncertainties of a large scale lignite fired power plant cycle and various measurement parameter sensitivities were investigated for five different design power outputs (100%, 85%, 80%, 60% and 40%) and with real data of the plant. For that purpose a black box method was employed considering coal flow with Lower Heating Value (LHV) as a single input and electricity produced as a single output of the plant. The uncertainty of energy and exergy efficiency of the plant was evaluated with this method by applying sensitivity analysis depending on the effect of measurement parameters such as LHV, coal mass flow rate, cell generator output voltage/current. In addition, an extreme case analysis was investigated to determine the maximum range of the uncertainties. Results of the black box method showed that uncertainties varied between 1.82-1.98% for energy efficiency and 1.32-1.43% for exergy efficiency of the plant at an operating power level of 40-100% of full power. It was concluded that LHV determination was the most important uncertainty source of energy and exergy efficiency of the plant. The uncertainties of the extreme case analysis were determined between 2.30% and 2.36% for energy efficiency while 1.66% and 1.70% for exergy efficiency for 40-100% power output respectively. Proposed method was shown to be an approach for understanding major uncertainties as well as effects of some measurement parameters in a large scale thermal power plant. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:399 / 406
页数:8
相关论文
共 50 条
  • [21] Exergy and Energy Analysis of a Dry Steam Power Plant with Heller Condenser
    Tempesti, D.
    Manfrida, G.
    Madiai, L.
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2014, 17 (01) : 7 - 13
  • [22] Exergy-energy analysis of full repowering of a steam power plant
    S. Nikbakht Naserabad
    K. Mobini
    A. Mehrpanahi
    M. R. Aligoodarz
    Frontiers in Energy, 2015, 9 : 54 - 67
  • [23] Energy, exergy and exergoeconomic analysis of a steam power plant: A case study
    Ameri, Mohammad
    Ahmadi, Pouria
    Hamidi, Armita
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) : 499 - 512
  • [24] Energy, exergy, and thermoeconomic analysis of a natural gas combined power plant
    Al-Dulaimi, Bashar Mohammed
    Bayat, Mutlucan
    Tekir, Mutlu
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024,
  • [25] Energy and exergy analyses of a supercritical power plant
    Hajidavalloo, Ebrahim
    Vosough, Amir
    INTERNATIONAL JOURNAL OF EXERGY, 2011, 9 (04) : 435 - 452
  • [26] Energy and exergy analysis of an aromatics plant
    Vilarinho, A. N.
    Campos, J. B. L. M.
    Pinho, C.
    CASE STUDIES IN THERMAL ENGINEERING, 2016, 8 : 115 - 127
  • [27] ENERGY AND EXERGY ANALYSIS OF DRY-STEAM GEOTHERMAL POWER PLANT IN KAMOJANG
    Utomo, Frandhoni
    Pambudi, Nugroho A.
    Setywan, Nova D.
    Basori
    Sumbodo, Wirawan
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2018, 38 (01): : 25 - 30
  • [28] Energy, exergy, and economic analysis of an integrated solar combined cycle power plant
    Benabdellah, Hamza Moussa
    Ghenaiet, Adel
    ENGINEERING REPORTS, 2021, 3 (11)
  • [29] Energy and exergy analysis of wind power plant: A case study of Gharo, Pakistan
    Tahir, Muhammad Faizan
    Chen Haoyong
    Han Guangze
    Mehmood, Kashif
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [30] The energy and exergy analysis of a combined parabolic solar dish - steam power plant
    Basem, Ali
    Moawed, Mohammed
    Abbood, Mohammed H.
    El-Maghlany, Wael M.
    RENEWABLE ENERGY FOCUS, 2022, 41 : 55 - 68