Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: Accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA)

被引:91
|
作者
Engelke, Klaus [1 ,2 ,3 ]
Libanati, Cesar [4 ]
Liu, Yu [4 ]
Wang, Huei [4 ]
Austin, Matt [4 ]
Fuerst, Tom [1 ,2 ]
Stampa, Bernd [1 ,2 ]
Timm, Wolfram [1 ,2 ]
Genant, Harry K. [1 ,2 ,5 ]
机构
[1] Synarc Inc, D-22087 Hamburg, Germany
[2] Synarc Inc, San Francisco, CA USA
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-8520 Erlangen, Germany
[4] Amgen Inc, Thousand Oaks, CA 91320 USA
[5] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
Quantitative computed tomography; Bone mineral density; Bone geometry; Distal radius; Osteoporosis; BONE-MINERAL DENSITY; POSTMENOPAUSAL WOMEN; DISTAL RADIUS; SEGMENTATION METHOD; CLINICAL-USE; OSTEOPOROSIS; FRACTURES; STRENGTH; AGE; RISK;
D O I
10.1016/j.bone.2009.03.669
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dual-energy X-ray absorptiometry (DXA) allows clinically relevant measurement of bone mineral density (BMD) at central and appendicular skeletal sites, but DXA has a limited ability to assess bone geometry and cannot distinguish between the Cortical and trabecular bone Compartments. Quantitative computed tomography (QCT) can supplement DXA by enabling geometric and compartmental bone assessments. Whole-body spiral CT scanners are widely available and require only seconds per scan, in contrast to peripheral QCT scanners, which have restricted availability, limited spatial resolution, and require several minutes of scanning time. This study evaluated the accuracy and precision of whole-body spiral CT scanners for quantitatively assessing the distal radius, a common site of non-vertebral osteoporosis-related fractures, and compared the CT-measured densitometric values with those obtained from dual-energy-X-ray absorptiometry. Subjects and methods: A total of 161 postmenopausal women with baseline lumbar spine BMD T-scores between -1.0 and -2.5 underwent left forearm QCT using whole-body spiral CT scanners twice, I month apart. QCT volumes of interest were defined and analyzed at 3 specific radial regions: the ultradistal region by using slices at 8, 9, and 10 mm proximal to the ulnar styloid tip; the distal region by a slice 20 mm proximal; and the middle region by a slice 40 mm proximal, BMD, bone mineral content (BMC), volume, and average cortical thickness and circumference were measured. We evaluated QCT accuracy and precision and also report correlations between QCT and DXA for BMD and BMC Results: Overall accuracy and precision errors for BMD, BMC and volume were consistent with known skeletal QCT technology precision and were generally less than 3%. BMD and BMC assessed by QCT and DXA were Correlated (r = 0.55 to 0.80). Discussion: Whole-body spiral CT scanners allow densitometric evaluations of the distal radius with good accuracy and very good precision. This original and convenient method provides a tool to further investigate cortical and trabecular bone variables in the peripheral skeleton in osteoporotic patients. These assessments, coupled with evaluation of the effects on cortical and trabecular bone measured in response to therapies for osteoporosis, may advance our understanding of the contributors to non-vertebral fracture Occurrence. (C) 2009 Published by Elsevier Inc.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [41] MEASUREMENT OF BODY COMPOSITION IN CATS USING COMPUTED TOMOGRAPHY AND DUAL ENERGY X-RAY ABSORPTIOMETRY
    Buelund, Lene E.
    Nielsen, Dorte H.
    McEvoy, Fintan J.
    Svalastoga, Eiliv L.
    Bjornvad, Charlotte R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (02) : 179 - 184
  • [42] Bone density measurements in children and adolescents - Quantitative computed tomography versus dual-energy X-ray absorptiometry
    Pitukcheewanont, P
    Chen, P
    ENDOCRINOLOGIST, 2005, 15 (04): : 232 - 239
  • [43] Accuracy and Precision of In Vivo Bone Mineral Measurements in Sheep Using Dual-Energy X-ray Absorptiometry
    J. M. Pouilles
    P. Collard
    F. Tremollieres
    P. Frayssinet
    J. J. Railhac
    J. P. Cahuzac
    A. Autefage
    C. Ribot
    Calcified Tissue International, 2000, 66 : 70 - 73
  • [44] Discordance in diagnosis of osteoporosis by quantitative computed tomography and dual-energy X-ray absorptiometry in Chinese elderly men
    Xu, Xiao-ming
    Li, Na
    Li, Kai
    Li, Xiao-Yu
    Zhang, Ping
    Xuan, Yan-jiao
    Cheng, Xiao-guang
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2019, 18 : 59 - 64
  • [45] Whole-body phantoms with anthropomorphic-shaped skeletons for evaluation of dual-energy X-ray absorptiometry measurements
    Shypailo, RJ
    Posada, JKJ
    Ellis, KJ
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 503 - 505
  • [46] Precision of a New Tool to Measure Visceral Adipose Tissue (VAT) Using Dual-Energy X-Ray Absorptiometry (DXA)
    Rothney, Megan P.
    Xia, Yi
    Wacker, Wynn K.
    Martin, Francois-Pierre
    Beaumont, Maurice
    Rezzi, Serge
    Giusti, Vittorio
    Ergun, David L.
    OBESITY, 2013, 21 (01) : E134 - E136
  • [47] Association of vertebral fractures with dual-energy x-ray arsorptiometry (DXA) and quantitative computed tomography (QCT) in postmenopausal women with glucocortic-induced osteoporosis (GIOP).
    Rehman, Q
    Lang, T
    Lane, NE
    ARTHRITIS AND RHEUMATISM, 2001, 44 (09): : S258 - S258
  • [48] Effect of Chemotherapy on Dual-Energy X-ray Absorptiometry (DXA) Body Composition Precision Error in Head and Neck Cancer Patients
    Chang, Ho-Chuen
    Lin, Yu-Ching
    Ng, Shu-Hang
    Cheung, Yun-Chung
    Wang, Cheng-Hsu
    Chen, Fang-Ping
    Chang, Hui-Ping
    Sung, Chen-Ming
    Fan, Chih-Ming
    Yeh, Kun-Yun
    Wu, Jim S.
    JOURNAL OF CLINICAL DENSITOMETRY, 2019, 22 (03) : 437 - 443
  • [49] Usefulness of Reflection Scanning in Determining Whole-Body Composition in Broadly Built Individuals Using Dual-Energy X-ray Absorptiometry
    Moco, Andreia V.
    Matias, Catarina N.
    Santos, Diana A.
    Rocha, Paulo M.
    Minderico, Claudia S.
    Cyrino, Edilson S.
    Sardinha, Luis B.
    Silva, Analiza M.
    JOURNAL OF CLINICAL DENSITOMETRY, 2019, 22 (03) : 429 - 436
  • [50] Regional skeletal muscle (SM) measurement: Evaluation of dual-energy x-ray absorptiometry (DXA) by computerized axial tomography (CT).
    Wang, ZM
    Wang, W
    Faith, M
    Kotler, D
    Shih, R
    Heymsfield, SB
    FASEB JOURNAL, 1999, 13 (04): : A262 - A262