Incoherent imaging with the soft X-ray microscope

被引:4
|
作者
Burge, RE
Yuan, XC
Morrison, GR
Charalambous, P
Browne, MT
An, Z
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Kings Coll London, Dept Phys, London WC2R 2LS, England
关键词
X-ray microscopy; zone plates; incoherent imaging;
D O I
10.1016/S0304-3991(99)00177-1
中图分类号
TH742 [显微镜];
学科分类号
摘要
The imaging characteristics for X-ray wavelengths in the "water window" under incoherent imaging conditions (large detector aperture) are examined for the King's College London scanning transmission X-ray microscope with zone-plate objective installed at the Daresbury (UK) synchrotron. The principal consideration was to express image theory, incorporating wave aberrations and apodised zone plates, and to apply the theory to experimental data. Comparisons are made, showing reasonable agreement, for a range of defocus values and two wavelengths. Due to problems in fabrication it was necessary to determine the effective, or operational, zone-plate parameters (radius of outermost active zone r(N), width of outermost active zone dr(N)); this was accomplished by through-focus series. Calculated point spread functions were used to deblurr images? in through-focus series of two-dimensional scanned X-ray images of specimen bores and test grating patterns. Significant contrast enhancement is achieved after deconvolution with a best point-to-point resolution of about 35 nm. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 92
页数:18
相关论文
共 50 条
  • [41] Imaging magnetic structures with a transmission X-ray microscope
    Fischer, P
    Eimüller, T
    Schütz, G
    Guttmann, P
    Schmahl, G
    Bayreuther, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 205 - 212
  • [42] Magnetic imaging with soft x-ray spectroholography
    Hellwig, O
    Eisebitt, S
    Eberhardt, W
    Schlotter, WF
    Lüning, J
    Stöhr, J
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
  • [43] Magnetic imaging with soft x-ray spectroholography
    Hellwig, Olav
    Eisebitt, Stefan
    Eberhardt, Wolfgang
    Schlotter, William F.
    Lüning, Jan
    Stöhr, Joachim
    Journal of Applied Physics, 2006, 99 (08):
  • [44] Soft X-ray TV microscope developed in China for NDT
    Tan, Kaisheng
    Li, Zigao
    Chen, Shaofeng
    NDT and E International, 1994, 27 (01): : 11 - 14
  • [45] Imaging of fine structures of cellular organelles in hydrated biological cells by a soft x-ray microscope combined with a fluorescence microscope
    Kado, Masataka
    Kishimoto, Maki
    Tamotsu, Satoshi
    Yasuda, Keiko
    Aoyama, Masato
    Shinohara, Kunio
    X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS X, 2013, 8849
  • [46] 3-d chemical imaging using angle-scan nanotomography in a soft X-ray scanning transmission X-ray microscope
    A. P. Hitchcock
    G. A. Johansson
    G. E. Mitchell
    M. H. Keefe
    T. Tyliszcak
    Applied Physics A, 2008, 92 : 447 - 452
  • [47] Soft X-Ray Spectromicroscopy Using Compact Scanning Transmission X-Ray Microscope at the Photon Factory
    Takeichi, Yasuo
    Ueno, Tetsuro
    Inami, Nobuhito
    Suga, Hiroki
    Takahashi, Yoshio
    Ono, Kanta
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [48] 3-d chemical imaging using angle-scan nanotomography in a soft X-ray scanning transmission X-ray microscope
    Hitchcock, A. P.
    Johansson, G. A.
    Mitchell, G. E.
    Keefe, M. H.
    Tyliszcak, T.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2008, 92 (03): : 447 - 452
  • [49] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography
    Wang, Y
    Jacobsen, C
    Maser, J
    Osanna, A
    JOURNAL OF MICROSCOPY-OXFORD, 2000, 197 : 80 - 93