共 50 条
The effects of nitrous oxide on the auditory evoked potential index during sevoflurane anaesthesia
被引:19
|作者:
Barr, G
Anderson, R
Jakobsson, J
[1
]
机构:
[1] Sabbatsbergs Hosp, Dept Anaesthesia, S-11382 Stockholm, Sweden
[2] Karolinska Hosp, Dept Cardiothorac Anaesthet & Intens Care, S-10401 Stockholm, Sweden
来源:
关键词:
anaesthetics;
volatile;
sevoflurane;
gases;
nitrous oxide;
monitoring;
evoked potentials;
D O I:
10.1046/j.1365-2044.2002.02693.x
中图分类号:
R614 [麻醉学];
学科分类号:
100217 ;
摘要:
We have studied the effects of nitrous oxide on the auditory evoked response index (AAI(TM)-index) derived from the A-line monitoring device during sevoflurane anaesthesia in 21 patients undergoing minor ambulatory surgery. During sevoflurane anaesthesia with an AAI(TM)-index < 30, the addition or withdrawal of nitrous oxide in a concentration of 66% end tidal did not show any linear dose dependent change in AAI(TM)-index. However, comparing nitrous oxide > 40% to nitrous oxide < 10% end tidal concentration the AAI(TM)-index did decrease, p < 0.05. The AAI(TM)-index is either non-linear at deeper anaesthetic levels or is insensitive to the anaesthetic effects of nitrous oxide in terms of MAC-multiples.
引用
收藏
页码:736 / 739
页数:4
相关论文