Silicon photomultipliers as readout for a segmented Time-of-Flight plastic detector

被引:4
|
作者
Cortes, M. L. [1 ,2 ,3 ]
Reese, M. [1 ,2 ]
Doublet, S. [1 ,4 ]
Saha, S. [1 ,2 ]
Schaffner, H. [2 ]
Ameil, F. [2 ]
Bednarczyk, P. [5 ]
Gerl, J. [2 ]
Gorska, M. [2 ]
Pietralla, N. [1 ]
Vesic, J. [2 ,6 ]
机构
[1] Tech Univ Darmstadt, Inst Kernphys, D-64289 Darmstadt, Germany
[2] GSI Helmoltzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany
[3] RIKEN, Nishina Ctr, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
[4] Ecole Cent Lyon, F-69134 Ecully, France
[5] IFJ PAN, PL-31342 Krakow, Poland
[6] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
Silicon photomultiplier; Plastic scintillator; Time resolution; Heavy-ion detection; Time-of-flight measurement; SCINTILLATION DETECTOR; 10; PS; RESOLUTION;
D O I
10.1016/j.nima.2018.05.031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Particle identification at radioactive ion beam facilities requires Time-of-Flight detectors with an optimal time resolution and high rate capability. Segmented plastic scintillators are a common option for such detectors. A promising approach to cope with the high segmentation of modern devices is the use of silicon photomultipliers (SiPMs) as readout of the Time-of-Flight detectors. A prototype device consisting of strips of plastic scintillator of 4.4 x 100 x 1 mm(3) readout at both ends by SiPMs of two different sizes was tested using a Xe-124 beam at 600 MeV/nucleon. Timing and time-over-threshold information were extracted. The time resolution of the prototype was found to vary with the applied voltage and the SiPM size. After optimizing the voltage, resolutions of 14.3(10) ps and 10.4(1) ps were obtained for SiPMs of 1 x 1 mm(2) and 3 x 3 mm(2) respectively. These results point to SiPMs being suitable as readout of plastic scintillators at radioactive ion beam facilities.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 50 条
  • [41] A test of silicon photomultipliers as readout for PET
    Otte, AN
    Barral, J
    Dolgoshein, B
    Hose, J
    Klemin, S
    Lorenz, E
    Mirzoyan, R
    Popova, E
    Teshima, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 705 - 715
  • [42] A Dedicated Readout ASIC for Time-of-Flight Positron Emission Tomography using Silicon Photomultiplier (SiPM)
    Chen, Huangshan
    Briggl, Konrad
    Fischer, Peter
    Gil, Alejandro
    Harion, Tobias
    Munwes, Yonathan
    Ritzert, Michael
    Schimansky, David
    Schultz-Coulon, Hans-Christian
    Shen, Wei
    Stankova, Vera
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [43] The Characteristics of Fast Scintillation Detectors of Time-of-Flight and Anticoincidence Systems of Space-Based Gamma-Ray Telescope GAMMA-400 with Silicon Photomultipliers Readout
    Arkhangelskiy, A. I.
    Galper, A. M.
    Arkhangelskaja, I. V.
    Baskov, V. A.
    Dalkarov, O. D.
    Korotkov, M. G.
    Leonov, A. A.
    L'vov, A. I.
    Pappe, N. Yu.
    Poliansky, V. V.
    Suchkov, S. I.
    Topchiev, N. P.
    Kheymits, M. D.
    Chasovikov, E. N.
    Yurkin, Yu. T.
    PHYSICS OF ATOMIC NUCLEI, 2023, 86 (05) : 810 - 816
  • [44] The Characteristics of Fast Scintillation Detectors of Time-of-Flight and Anticoincidence Systems of Space-Based Gamma-Ray Telescope GAMMA-400 with Silicon Photomultipliers Readout
    A. I. Arkhangelskiy
    A. M. Galper
    I. V. Arkhangelskaja
    V. A. Baskov
    O. D. Dalkarov
    M. G. Korotkov
    A. A. Leonov
    A. I. L‘vov
    N. Yu. Pappe
    V. V. Poliansky
    S. I. Suchkov
    N. P. Topchiev
    M. D. Kheymits
    E. N. Chasovikov
    Yu. T. Yurkin
    Physics of Atomic Nuclei, 2023, 86 : 810 - 816
  • [45] Readout Electronics and Data Acquisition of a Positron Emission Tomography Time-of-Flight Detector Module With Waveform Digitizer
    Yeom, Jung Yeol
    Vinke, Ruud
    Spanoudaki, Virginia Ch
    Hong, Key Jo
    Levin, Craig S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3735 - 3741
  • [46] ON THE LIMITS OF THE PERFORMANCES OF TIME-OF-FLIGHT SCINTILLATOR HODOSCOPES SAVING THE NUMBER OF PHOTOMULTIPLIERS
    CARIA, M
    MACCIOTTA, P
    MARCELLO, S
    PUDDU, G
    SERCI, S
    BRESSANI, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 609 - 611
  • [47] Time-of-Flight Characteristics of Scintillation Counters with Fine-Mesh Photomultipliers
    A. V. Akindinov
    Yu. T. Kiselev
    A. N. Martem'yanov
    V. I. Ushakov
    Instruments and Experimental Techniques, 2003, 46 : 345 - 350
  • [48] Time-of-flight characteristics of scintillation counters with fine-mesh photomultipliers
    Akindinov, AV
    Kiselev, YT
    Martem'yanov, AN
    Ushakov, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (03) : 345 - 350
  • [49] A Time-of-Flight detector in CDF-II
    Acosta, D
    Ahn, M
    Anikeev, K
    Bauer, G
    Bellettini, G
    Cabrera, S
    Cerri, C
    Dececco, S
    Depedis, D
    DiGirolamo, A
    Dionisi, C
    Fernandez, J
    Furic, IK
    Chen, C
    Cho, I
    Giagu, S
    Gomez, G
    Grozis, C
    Jones, M
    Kaneko, H
    Kazama, A
    Kephart, R
    Kim, DH
    Kim, BJ
    Kim, MS
    Kim, S
    Kim, SB
    Kim, YK
    Konigsberg, J
    Kononenko, W
    Korn, A
    Kravchenko, I
    Kroll, J
    Lee, J
    Lewis, J
    Madorsky, A
    Mayers, GM
    Menzione, A
    Mulhearn, M
    Newcomer, FM
    Oh, Y
    Oldeman, RGC
    Paus, C
    Pavlon, S
    Piedra, J
    Rescigno, M
    Rodrigo, T
    Ruiz, A
    Sato, K
    Sato, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 605 - 608
  • [50] NEW DETECTOR FOR TIME-OF-FLIGHT MASS SPEC
    不详