Basic study on velocity-flow urodynamics using Doppler sonography: Simultaneous detection of cavitation and Doppler signals in an artificial urethral model

被引:5
|
作者
Kumon, H
Ozawa, H
Nose, H
Ohta, H
Nishigaki, K
机构
[1] Okayama Univ, Grad Sch Med & Dent, Dept Urol, Okayama 7008558, Japan
[2] Kobe Univ, Dept Mercantile Marine, Superconductor Sci Lab, Hyogo, Japan
关键词
cavitation; Doppler ultrasonography; urethra; urodynamics;
D O I
10.1111/j.1442-2042.2004.00858.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: We have developed velocity-flow urodynamics using Doppler sonography based on the hypothesis that microbubbles formed in the urethra are responsible for Doppler signals. In order to confirm this hypothesis derived from Bernoulli's principle, we investigated the simultaneous detection of cavitation noise and Doppler signals in an experimental system. Methods: An experimental circuit was built in which a stenosis was created using a glass or silicon tube with tap water used as the sample fluid. Doppler signals, pressure before and after the stenosis, flow rate, flow velocity and cavitation noise were measured. Direct detection of cavitation with a high-speed charged-coupled device (CCD) camera was conducted in the glass tube. The relationship between cross-sectional area and flow velocity in terms of the detection of Doppler signals was analyzed in the silicon tube study. Results: In the glass tube study, a high-speed CCD camera clearly detected masses of microbubbles associated with cavitation. The range of flow rates creating cavitation completely corresponded with those producing Doppler signals detected by ultrasonography. A similar correlation was observed in the silicon tube study, which showed that a low flow velocity of 41.5 cm/sec through a stenosis with a cross-sectional area of 20 mm(2) created Doppler signals at a flow rate of 8.3 mL/sec. Conclusion: The results of the present study confirmed that microbubbles created in flowing urine are responsible for Doppler signals. Measurement of velocity-flow urodynamics has great potential to become a non-invasive and reliable alternative to conventional pressure- flow urodynamic studies.
引用
收藏
页码:628 / 633
页数:6
相关论文
共 50 条
  • [21] Calculation of pulmonary artery mean pressure using a mathematical model and Doppler data: A simultaneous catheter and Doppler study
    Selimovic, N.
    Rundqvist, B.
    Petersson, S.
    Wallentin, J.
    Bech-Hanssen, O.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S174 - S174
  • [22] Intracranial Blood Flow Velocity in Patients with beta-Thalassemia Intermedia Using Transcranial Doppler Sonography: A Case-Control Study
    Ashjazadeh, Nahid
    Emami, Sajad
    Petramfar, Peyman
    Yaghoubi, Ehsan
    Karimi, Mehran
    ANEMIA, 2012, 2012
  • [23] RATE OF SUCCESSFUL RECORDING OF BLOOD-FLOW SIGNALS IN THE MIDDLE CEREBRAL-ARTERY USING TRANSCRANIAL DOPPLER SONOGRAPHY
    ITOH, T
    MATSUMOTO, M
    HANDA, N
    MAEDA, H
    HOUGAKU, H
    HASHIMOTO, H
    ETANI, H
    TSUKAMOTO, Y
    KAMADA, T
    STROKE, 1993, 24 (08) : 1192 - 1195
  • [24] Study on oscillating flow of moderate kinetic Reynolds numbers using complex velocity model and phase Doppler anemometer
    Xiao, Gang
    Zhou, Tianxue
    Ni, Mingjiang
    Chen, Conghui
    Luo, Zhongyang
    Cen, Kefa
    APPLIED ENERGY, 2014, 130 : 830 - 837
  • [25] Detection of mammary blood flow changes by transrectal colour Doppler sonography in an E. coli mastitis model
    Potapow, A.
    Schmauder, S.
    Petzl, W.
    Sauter-Louis, C.
    Friker, J.
    Nautrup, C. Poulsen
    Zerbe, H.
    REPRODUCTION IN DOMESTIC ANIMALS, 2008, 43 : 25 - 25
  • [26] Detection of femoral artery occlusion from spectral density of Doppler signals using the artificial neural network
    Kara, S
    Kemaloglu, S
    Güven, AE
    EXPERT SYSTEMS WITH APPLICATIONS, 2005, 29 (04) : 945 - 952
  • [27] Can transthoracic color Doppler echocardiography with a high-frequency transducer reliably measure coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery? A simultaneous Doppler guide wire and Doppler echocardiographic study
    Hozumi, T
    Yoshida, K
    Asami, Y
    Ogata, Y
    Kawamoto, T
    CIRCULATION, 1998, 98 (17) : 783 - 783
  • [28] Improvement of the detection of human pulpal blood flow using a laser Doppler flowmeter modified for low flow velocity
    Qu, Xiaofu
    Ikawa, Motohide
    Shimauchi, Hidetoshi
    ARCHIVES OF ORAL BIOLOGY, 2014, 59 (02) : 199 - 206
  • [29] Simultaneous measurements of velocity and stress distributions in polyisobutylenes using laser-Doppler velocimetry and flow induced birefringence
    Stefan Schuberth
    Helmut Münstedt
    Rheologica Acta, 2008, 47 : 111 - 119
  • [30] Simultaneous measurements of velocity and stress distributions in polyisobutylenes using laser-Doppler velocimetry and flow induced birefringence
    Schuberth, Stefan
    Muenstedt, Helmut
    RHEOLOGICA ACTA, 2008, 47 (01) : 111 - 119