Parametric study of irreversible Stirling and Ericsson cryogenic refrigeration cycles

被引:41
|
作者
Tyagi, SK
Kaushik, SC
Singhal, MK
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] SSV PG Coll, Dept Phys, Ghaziabad 245101, UP, India
关键词
internal irreversibility parameter; Stirling and Ericsson cryogenic refrigeration cycles; optimum performance;
D O I
10.1016/S0196-8904(01)00181-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This communication presents a parametric study of irreversible Stirling and Ericsson cryogenic refrigerator cycles including external and internal irreversibilities along with finite heat capacities of external reservoirs. The external irreversibility is due to finite temperature difference between the working fluid and external fluids in the source/sink reservoirs, while the internal irreversibilities are due to regenerative heat loss and other entropy generations in the cycle. The cooling load is maximized for the given power input. The cooling coefficient of performance, the heat transfers to and from the refrigerator and the working fluid temperatures at these conditions have been evaluated. The effect of different parameters (reservoirs fluid temperature, the effectivenesses, heat capacitance rates of the external reservoirs and irreversibility parameter) on the performance of these cycles has been studied. It is found that the effect of the internal irreversibility parameter is more pronounced than that of other parameters. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:2297 / 2309
页数:13
相关论文
共 50 条
  • [21] Thermodynamic analysis and optimization of an irreversible Ericsson cryogenic refrigerator cycle
    Ahmadi, Mohammad Hossein
    Ahmadi, Mohammad Ali
    ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 147 - 155
  • [22] Class of internally irreversible refrigeration cycles
    Algeria and Univ of Michigan, Ann Arbor, United States
    J Phys D, 3 (593-599):
  • [23] A class of internally irreversible refrigeration cycles
    AitAli, MA
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (03) : 593 - 599
  • [24] Optimization analysis of the performance of an irreversible Ericsson refrigeration cycle in the micro/nanoscale
    Wang, Hao
    Wu, Guoxing
    Fu, Yueming
    PHYSICA SCRIPTA, 2011, 84 (04)
  • [25] Optimal thermoeconomic performance of an irreversible regenerative ferromagnetic Ericsson refrigeration cycle
    Xu, Zhichao
    Guo, Juncheng
    Lin, Guoxing
    Chen, Jincan
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2016, 409 : 71 - 79
  • [26] Thermoeconomic optimization and parametric study of an irreversible Stirling heat pump cycle
    Tyagi, SK
    Chen, JC
    Kaushik, SC
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (01) : 105 - 112
  • [27] Thermoeconomic optimization of an irreversible Stirling cryogenic refrigerator cycle
    Tyagi, SK
    Lin, G
    Kaushik, SC
    Chen, J
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 924 - 931
  • [28] General performance characteristics of an irreversible ferromagnetic Stirling refrigeration cycle
    Lin, G
    Tegus, O
    Zhang, L
    Brück, E
    PHYSICA B-CONDENSED MATTER, 2004, 344 (1-4) : 147 - 156
  • [29] Parametric optimization of an irreversible magnetic Ericsson refrigerator with finite heat reservoirs
    Ye, X. M.
    Lin, G. X.
    Chen, J. C.
    Bruck, E.
    PHYSICA B-CONDENSED MATTER, 2007, 391 (02) : 350 - 356
  • [30] A new thermoeconomic approach and parametric study of an irreversible regenerative Brayton refrigeration cycle
    Tyagi, S. K.
    Chen, G. M.
    Wang, Q.
    Kaushik, S. C.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (07): : 1167 - 1174