Parametric study of irreversible Stirling and Ericsson cryogenic refrigeration cycles

被引:41
|
作者
Tyagi, SK
Kaushik, SC
Singhal, MK
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] SSV PG Coll, Dept Phys, Ghaziabad 245101, UP, India
关键词
internal irreversibility parameter; Stirling and Ericsson cryogenic refrigeration cycles; optimum performance;
D O I
10.1016/S0196-8904(01)00181-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This communication presents a parametric study of irreversible Stirling and Ericsson cryogenic refrigerator cycles including external and internal irreversibilities along with finite heat capacities of external reservoirs. The external irreversibility is due to finite temperature difference between the working fluid and external fluids in the source/sink reservoirs, while the internal irreversibilities are due to regenerative heat loss and other entropy generations in the cycle. The cooling load is maximized for the given power input. The cooling coefficient of performance, the heat transfers to and from the refrigerator and the working fluid temperatures at these conditions have been evaluated. The effect of different parameters (reservoirs fluid temperature, the effectivenesses, heat capacitance rates of the external reservoirs and irreversibility parameter) on the performance of these cycles has been studied. It is found that the effect of the internal irreversibility parameter is more pronounced than that of other parameters. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:2297 / 2309
页数:13
相关论文
共 50 条