Dynamic contrast-enhanced MRI measurement of renal function in healthy participants

被引:20
|
作者
Eikefjord, Eli [1 ,2 ]
Andersen, Erling [1 ,3 ]
Hodneland, Erlend [2 ,4 ]
Hanson, Erik A. [5 ]
Sourbron, Steven [6 ]
Svarstad, Einar [2 ,7 ]
Lundervold, Arvid [1 ,8 ]
Rorvik, Jarle T. [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Radiol, Jonas Lies Vei 65, NO-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] Haukeland Hosp, Dept Clin Engn, Bergen, Norway
[4] Christian Michelsen Res CMR AS, Bergen, Norway
[5] Univ Bergen, Dept Math, Bergen, Norway
[6] Univ Leeds, Fac Med & Hlth, Leeds, W Yorkshire, England
[7] Haukeland Hosp, Dept Med, Bergen, Norway
[8] Univ Bergen, Dept Biomed, Bergen, Norway
关键词
Urinary; MR functional imaging; kidney; adults; imaging sequence; technology assessment; GLOMERULAR-FILTRATION-RATE; SINGLE KIDNEY-FUNCTION; DCE-MRI; RENOGRAPHY; GFR; MODEL; REPRODUCIBILITY; RESPONSES; PERFUSION; IOHEXOL;
D O I
10.1177/0284185116666417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High repeatability, accuracy, and precision for renal function measurements need to be achieved to establish renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as a clinically useful diagnostic tool. Purpose: To investigate the repeatability, accuracy, and precision of DCE-MRI measured renal perfusion and glomerular filtration rate (GFR) using iohexol-GFR as the reference method. Material and Methods: Twenty healthy non-smoking volunteers underwent repeated DCE-MRI and an iohexol-GFR within a period of 10 days. Single-kidney (SK) MRI measurements of perfusion (blood flow, Fb) and filtration (GFR) were derived from parenchymal intensity time curves fitted to a two-compartment filtration model. The repeatability of the SK-MRI measurements was assessed using coefficient of variation (CV). Using iohexol-GFR as reference method, the accuracy of total MR-GFR was determined by mean difference (MD) and precision by limits of agreement (LoA). Results: SK-Fb (MR1, 345 +/- 84; MR2, 371 +/- 103 mL/100 mL/min) and SK-GFR (MR1, 52 +/- 14; MR2, 54 +/- 10 mL/min/ 1.73m(2)) measurements achieved a repeatability (CV) in the range of 15-22%. With reference to iohexol-GFR, MR-GFR was determined with a low mean difference but high LoA (MR1, MD 1.5 mL/min/1.73m(2), LoA [-42, 45]; MR2, MD 6.1 mL/min/1.73m(2), LoA [-26, 38]). Eighty percent and 90% of MR-GFR measurements were determined within +/- 30% of the iohexol-GFR for MR1 and MR2, respectively. Conclusion: Good repeatability of SK-MRI measurements and good agreement between MR-GFR and iohexol-GFR provide a high clinical potential of DCE-MRI for renal function assessment. A moderate precision in MR-derived estimates indicates that the method cannot yet be used in clinical routine.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [21] Dynamic contrast-enhanced MRI of ocular melanoma
    Jiang, Xuyuan
    Asbach, Patrick
    Willerding, Gregor
    Dulce, Miriam
    Xu, Ke
    Taupitz, Matthias
    Hamm, Bernd
    Erb-Eigner, Katharina
    MELANOMA RESEARCH, 2015, 25 (02) : 149 - 156
  • [22] Chronic Urinary Obstruction: Evaluation of Dynamic Contrast-enhanced MR Urography for Measurement of Split Renal Function
    Claudon, Michel
    Durand, Emmanuel
    Grenier, Nicolas
    Prigent, Alain
    Balvay, Daniel
    Chaumet-Riffaud, Philippe
    Chaumoitre, Kathia
    Cuenod, Charles-Andre
    Filipovic, Marina
    Galloy, Marie-Agnes
    Lemaitre, Laurent
    Mandry, Damien
    Micard, Emilien
    Pasquier, Cedric
    Sebag, Guy H.
    Soudant, Marc
    Vuissoz, Pierre-Andre
    Guillemin, Francis
    RADIOLOGY, 2014, 273 (03) : 801 - 812
  • [23] Localized Measurement of Atherosclerotic Plaque Inflammatory Burden With Dynamic Contrast-Enhanced MRI
    Chen, Huijun
    Cai, Jianming
    Zhao, Xihai
    Underhill, Hunter
    Ota, Hideki
    Oikawa, Minako
    Dong, Li
    Yuan, Chun
    Kerwin, William S.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 567 - 573
  • [24] Quantitative Estimation of Renal Function with Dynamic Contrast-Enhanced MRI Using a Modified Two-Compartment Model
    Chen, Bin
    Zhang, Yudong
    Song, Xiaojian
    Wang, Xiaoying
    Zhang, Jue
    Fang, Jing
    PLOS ONE, 2014, 9 (08):
  • [25] Myocardial microvascular function at rest and stress measured with dynamic contrast-enhanced MRI
    David A Broadbent
    John D Biglands
    Abdulghani M Larghat
    Steven Sourbron
    Sven Plein
    David L Buckley
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [26] Assessment of ameloblastomas using MRI and dynamic contrast-enhanced MRI
    Asaumi, J
    Hisatomi, M
    Yanagi, Y
    Matsuzaki, H
    Choi, YS
    Kawai, N
    Konouchi, H
    Kishi, K
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (01) : 25 - 30
  • [27] Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects
    Buckley, David L.
    Shurrab, Ala'a E.
    Cheung, Ching M.
    Jones, Andrew P.
    Mamtora, Hari
    Kalra, Philip A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 1117 - 1123
  • [28] Contrast-enhanced mammography in comparison with dynamic contrast-enhanced MRI: which modality is appropriate for whom?
    Kamal, Rasha
    Mansour, Sahar
    Farouk, Amr
    Hanafy, Mennatallah
    Elhatw, Ahmed
    Goma, Mohammed Mohammed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [29] Contrast-enhanced mammography in comparison with dynamic contrast-enhanced MRI: which modality is appropriate for whom?
    Rasha Kamal
    Sahar Mansour
    Amr Farouk
    Mennatallah Hanafy
    Ahmed Elhatw
    Mohammed Mohammed Goma
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [30] Renal and systemic pH imaging by contrast-enhanced MRI
    Raghunand, N
    Howison, C
    Sherry, AD
    Zhang, SR
    Gillies, RJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 249 - 257